KHALIK, IDHAM and Prayudi, Prayudi and SUDIRMANTO, SUDIRMANTO (2016) ANALISA UNJUK KERJA BOILER FEED PUMP TURBINE DRIVEN DIBANDING DENGAN MOTOR DRIVEN PADA PLTU BANTEN 3 LONTAR. Diploma thesis, ITPLN.
FULL SKRIPSI.pdf
Restricted to Registered users only
Download (1MB)
DAFTAR ISI.pdf
Download (461kB)
COVER SKRIPSI.pdf
Download (184kB)
Abstract
Pusat Listrik Tenaga Uap (PLTU) merupakan jenis Pembangkit Listrik yang paling banyak dijumpai dan hampir sebagian besar kebutuhan energi listrik di pulau Jawa dan Bali disuplai oleh jenis pembangkit tersebut. Secara garis besar sistem pembangkit listrik tenaga uap terdiri dari peralatan utama dan peralatan pendukung. Salah satu bagian peralatan pembangkit listrik tenaga uap yang berperan utama adalah Boiler Feed Pump (BFP). Fungsi utama BFP adalah memompa fluida dari Deaerator menuju ke Boiler Steam Drum melalui High Pressure Heater dan Economizer. BFP Pada PLTU Banten 3 Lontar menggunakan dua tipe penggerak pompa, yang pertama menggunakan mini turbin (Turbine Driven) dan yang kedua menggunakan motor listrik (Motor Driven) sebagai penggeraknya. Dalam hal ini BFP akan menghasilkan performa yang berbeda antara BFP Turbine Driven dengan Motor Driven. Dalam menganalisis performa pompa diperlukan parameter-parameter seperti kapasitas, tinggi tekan fluida, daya yang dibutuhkan untuk memutar pompa, efisiensi dan lain-lain. Dari hasil analisa dengan menggunakan nilai kapasitas aliran yang sama menunjukan bahwa besarnya head total pada BFP Turbin driven lebih besar daripada Motor Driven dan dari segi pemakaian energi Turbin Driven jauh lebih efisien karena hanya membutuhan energi sebesar 2308 kW dibandingkan dengan BFP Motor Driven yang menggunakan energi sebesar 2.375 kW.
Steam Power (Power Plant) is a type of Power Plant is the most common and most of the electric energy needs in the island of Java and Bali are supplied by the plant type. Broadly speaking, thermal power generation system consists of main equipment and ancillary equipment. One piece of equipment steam power plants are the main yangberperan Boiler Feed Pump (BFP). BFP main function is to pump fluid from deaerator heading to Steam Boiler Drum through High Pressure Heater and economizer. BFP In Banten power plant 3 Lontar Using two types of pump drive, the first using the mini turbine (Turbine Driven) and the second uses an electric motor (Motor Driven) as a vehicle. In this case the BFP will produce a different performance between BFP Turbine Driven by Motor Driven. In analyzing the performance of pumps required parameters such as capacity, high-pressure fluid, the power needed to rotate the pump, efficiency and others. From the analysis using the same flow capacity value indicates that the magnitude of the total head at the BFP turbine driven outweigh Motor Driven and in terms of energy consumption Turbine Driven far more efficient because only need at an energy of 2308 kW compared to the use BFP Motor Driven an energy of 2,375 kW.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | PLTU, Boiler Feed Pump, Turbine Driven, Motor Driven. Steam Power Plant, Boiler Feed Pump Turbine Driven, Motor Driven. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Mesin |
| Divisions: | Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin |
| Depositing User: | Nurul Hidayati |
| Date Deposited: | 11 May 2026 09:57 |
| Last Modified: | 11 May 2026 09:57 |
| URI: | https://repository.itpln.ac.id/id/eprint/2710 |