PERBAIKAN KABEL POWER 20 KV TERHADAP GANGGUAN FLASHOVER PADA TRAFO DAYA UNIT 3 DI PT. PLN (PERSERO) P3B SUMATERA UPT BANDA ACEH

MUNANDAR, MALIK and Sukmajati, Sigit (2022) PERBAIKAN KABEL POWER 20 KV TERHADAP GANGGUAN FLASHOVER PADA TRAFO DAYA UNIT 3 DI PT. PLN (PERSERO) P3B SUMATERA UPT BANDA ACEH. Diploma thesis, ITPLN.

[thumbnail of Proyek Akhir_Malik Munandar_201971032_RIVISI SIDANG.pdf] Text
Proyek Akhir_Malik Munandar_201971032_RIVISI SIDANG.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Pada kabel power 20 kV di trafo daya unit 3 di PT. PLN (Persero) P3B Sumatera UPT Banda Aceh mengalami gangguan flashover pada fasa S dan fasa T, yang menyebabkan pemadaman dan ketidakstabilan sistem selama 34 menit dan mengurangi keandalan penyulang serta menurunnya sistem instalasi listrik. Gangguan flashover ini sulit untuk dihindari, kabel mengalami kerusakan total akibat terbakar pada sisi terminasi. Maka dari itu dilakukannya penelitian untuk mengetahui penyebab munculnya flashover pada kabel power 20 kV di trafo daya unit 3. Serta dengan melakukan perbaikan pada kabel power 20 kV di trafo daya unit 3 fasa S dan fasa T yang mengalami gangguan flashover. Untuk itu diperlukanlah pengujian dan pemeliharaan pada kabel power 20 kV di trafo daya unit 3, salah satunya dengan melakukan pengujian tan delta yang berguna untuk mengetahui kondisi dan nilai keandalan pada isolasi kabel. Pengujian ini dilakukan untuk mengetahui nilai kualitas isolasi pada kabel power 20 kV di trafo daya unit 3 gardu induk Banda Aceh. Dari hasil pengujian tan delta nilai kabel power 20 kV pada saat sebelum dilakukannya perbaikan pada fasa S sebesar 2,28% dan pada fasa T sebesar 2,19%, yang mana nilai tersebut sangat jauh dari nilai standar menurut ANSI C 57.12.90 yaitu kurang dari 0,5% dan hasil tersebut merupakan nilai yang buruk. Dilihat dari hasil pengujian tan delta pada saat pemeliharaan 2 tahunan yang dilakukan 14 bulan yang lalu sebelum kejadian gangguan flashover ini, menunjukkan bahwa pada fasa R menghasilkan nilai tan delta sebesar 0,16% yang dimana kabel dinyatakan dalam kondisi baik atau masih dalam batas standarnya yaitu kurang dari 0,5%. Sedangkan pada fasa T dan S menghasilkan nilai tan delta sebesar 0,68% pada fasa S dan 0,62% pada T, hal ini menunjukkan bahwa kondisi isolasi kabel pada fasa S dan T sudah mengalami penurunan, yang mana nilai tersebut menjadi tanda bahwa kabel tersebut mengalami kegagalan isolasi yang diakibatkan adanya rongga pada isolasi kabel.

On the 20 kV power cable in the unit 3 power transformer at PT. PLN (Persero) P3B Sumatra UPT Banda Aceh experienced flashover disturbances in phase S and phase T, which caused blackouts and system instability for 34 minutes and reduced the reliability of the feeder and decreased the electrical installation system. This flashover disturbance is difficult to avoid, the cable is completely damaged due to fire on the termination side. Therefore, a study was conducted to determine the cause of the emergence of flashovers on the 20 kV power cable in the unit 3 power transformer. And by making repairs to the 20 kV power cable in the 3 phase S and T phase unit power transformers that experienced flashover disturbances. For this reason, it is necessary to test and maintain the 20 kV power cable in the unit 3 power transformer, one of which is by conducting a tan delta test which is useful for determining the condition and reliability value of the cable insulation. This test was conducted to determine the value of the insulation quality on the 20 kV power cable in the power transformer unit 3 of the Banda Aceh substation. From the results of the tan delta test, the value of the 20 kV power cable before the repair was carried out in the S phase was 2.28% and the T phase was 2.19%, which is very far from the standard value according to ANSI C 57.12.90 which is less of 0.5% and the result is a poor value. Judging from the results of the tan delta test during the 2-year maintenance carried out 14 months ago before the flashover disturbance incident, it shows that the R phase produces a tan delta value of 0.16% where the cable is stated to be in good condition or still within its standard limits, namely less than 0.5%. While the T and S phases produce a tan delta value of 0.68% in the S phase and 0.62% in the T, this indicates that the condition of the cable insulation in the S and T phases has decreased, which is a sign that the cable The case experienced an insulation failure caused by a cavity in the cable insulation.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: kabel power, gangguan, perbaikan power cable, disturbance, repairs
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 07 Apr 2026 03:06