PENGUJIAN TAHANAN ISOLASI DAN TEGANGAN TEMBUS PADA TRANSFORMATOR 20kV DI PT.PLN (PERSERO) UNIT PELAKSANA PELAYANAN PELANGGAN TANJUNG PRIOK

PRIATAMA, LINTANG and Widyastuti, Christine (2022) PENGUJIAN TAHANAN ISOLASI DAN TEGANGAN TEMBUS PADA TRANSFORMATOR 20kV DI PT.PLN (PERSERO) UNIT PELAKSANA PELAYANAN PELANGGAN TANJUNG PRIOK. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_LINTANGPRIATAMA_201971160_LINTANG PRIATAMA.pdf] Text
PROYEK AKHIR_LINTANGPRIATAMA_201971160_LINTANG PRIATAMA.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Transformator merupakan peralatan listrik yang digunakan dalam mentransformasikan tegangan yaitu dari tegangan rendah ke tegangan tinggi maupun sebaliknya tegangan tinggi ke rendah. Kegagalan bekerjanya transformator distribusi dapat pengaruhi oleh waktu dan usia transformator. Oleh karena itu maka diperlukan dilakukannya pemeliharaan terhadap transformator distribusi guna mengetahui kondisi transformator. Pengujian yang dilakukan salah satunya adalah pengujian tahanan isolasi dan pengujian tegangan tembus. Pengujian tahanan isolasi bertujuan untuk mengetahui kondisi isolasi dari suatu peralatan tersebut, faktor yang mempengaruhi nilai dari tahanan isolasi adalah kotoran, kelembaban, dan kerusakan pada komponen pada transformator. Berdasarkan standar IEEE 43-2013 pengujian tahanan isolasi dikatakan baik jika nilai sudah melebihi dari >2,1 GΩ dan dikatakan buruk jika nilainya kurang dari 1000 x tegangan kerjanya serta nilai tegangan tembusnya 36 kV tidak memenuhi standar.

Transformer is an electrical equipment used in transforming voltage from low voltage to high voltage and vice versa high to low voltage. The failure of the distribution transformer to work can be affected by the time and age of the transformer. Therefore, it is necessary to do maintenance on the distribution transformer in order to determine the condition of the transformer. One of the tests carried out is insulation resistance testing and breakdown voltage testing. Insulation resistance testing aims to determine the condition of the insulation of the equipment, the factors that affect the value of the insulation resistance are dirt, moisture, and damage to components on the transformer. Based on the IEEE 43-2013 standard, the insulation resistance test is said to be good if the value exceeds >2.1 GΩ and is said to be bad if the value is less than 1000 x working voltage and the breakdown voltage value of 36 kV does not meet the standard.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Tahanan Isolasi, Tegangan Tembus, Transformator Distribusi. Insulation resistance, Breakdown voltage, Distribution Transformer
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 07 Apr 2026 03:30
Last Modified: 07 Apr 2026 03:30
URI: https://repository.itpln.ac.id/id/eprint/6371