JAELANI, HAERUDIN and junaidi, andi (2022) PENGUJIAN TAHANAN ISOLASI, TAHANAN KONTAK, DAN KESEREMPAKAN PEMUTUS TENAGA 150kV PENGHANTAR CIKANDE I PADA GARDU INDUK PUNCAK ARDI MULYA. Diploma thesis, ITPLN.
Proyek Akhir_Haerudin Jaelani_201871068_HAERUDIN JAELANI.pdf
Restricted to Registered users only
Download (3MB)
Abstract
sistem proteksi bertujuan untuk mengamankan peralatan listrik maupun manusia yang berada di sekitar area gangguan (hubung singkat). Peralatan proteksi bekerja mengisolir arus gangguan yang terjadi secepat mungkin dan seminimal mungkin agar tidak terjadi kerusakan yang lebih besar. Salah satu peralatan yang termasuk didalam sistem proteksi adalah pemutus tenaga (PMT). Penelitian ini bertujuan untuk menguji tahanan isolasi, tahanan kontak serta keserempakaan PMT. Penelitian ini dilakukan dengan menggunakan metode observasi kemudian melakukan pengambilan data di Gardu Induk 150kV Puncak Ardi Mulya,data yang didapat dianalisa menggunakan metode analisa kuantitatif dengan dihitung,dibandingkan dengan data pengujian sebelumnya tahun 2020 dan 2018. Dari analisis hasil pengujian dapat diketahui bahwa pemutus tenaga di Gardu Induk Puncak Ardi Mulya masih layak dan bekerja dengan baik. Nilai ujui rata rata tahanan isolasi untuk R (177GΩ) S (164 GΩ) T (157 GΩ). Untuk nilai uji tahanan kontak didapat R (38.1µΩ) S (39.5 µΩ) T (38.94 µΩ), sedangkan nilai uji keserempakaan PMT pada saat close didapat R (72ms) S (73ms) T (71.5ms) kemudian hasil keserempaakn pada saat open didapat R (30ms) S (30ms) T (30ms). Dari hasil pengujian dan melalui analisa yang telah di lakukan menyatakan PMT Gardu Idnuk 150 Kv Puncak Ardi Mulya masih dalam keadaan baik.
the protection system aims to secure electrical equipment and humans in the vicinity of the disturbance area (short circuit). The protection equipment works to isolate the fault current that occurs as quickly as possible and to a minimum so that no greater damage occurs. One of the equipment included in the protection system is a power breaker (PMT). This study aims to test the insulation resistance, contact resistance and PMT synchronously. This research was carried out using the observation method and then taking data at the 150kV Substation Puncak Ardi Mulya, the data obtained was analyzed using a quantitative analysis method by calculating, compared to the previous test data in 2020 and 2018. From the analysis of the test results it can be seen that the power breaker in The Ardi Mulya Peak Substation is still feasible and working well. The average test value of insulation resistance for R (177GΩ) S (164 GΩ) T (157 GΩ). For the contact resistance test value, R (38.1 ) S (39.5 ) T (38.94 ) was obtained, while the PMT synchronously test value at the time of close was obtained R (72ms) S (73ms) T (71.5ms) then the results were simultaneous when open. get R (30ms) S (30ms) T (30ms). From the test results and through the analysis that has been done, it states that PMT Substation Idnuk 150 Kv Puncak Ardi Mulya is still in good condition.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Proteksi,Pemutus Tenaga (PMT), Pengujian protection,Power Circuit Breaker (PMT), Testing |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 07 Apr 2026 03:45 |
| Last Modified: | 07 Apr 2026 03:45 |
| URI: | https://repository.itpln.ac.id/id/eprint/6375 |