PENGUJIAN TITIK HOTSPOT DENGAN MENGGUNAKAN METODE THERMOVISI PADA GARDU INDUK CILEDUG 150 KV

WAHYUSAPUTRA, ERLANGGA and Diantari, Retno Aita (2022) PENGUJIAN TITIK HOTSPOT DENGAN MENGGUNAKAN METODE THERMOVISI PADA GARDU INDUK CILEDUG 150 KV. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_ERLANGGA WAHYUSAPUTRA_201971005_ERLANGGA WAHYUSAPUTR.pdf] Text
PROYEK AKHIR_ERLANGGA WAHYUSAPUTRA_201971005_ERLANGGA WAHYUSAPUTR.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Perlengkapan gardu induk atau gardu induk yang mampu menghantarkan arus menjadi panas karena rugi arus akibat resistansi konduktor. Switchgear memiliki terminal dan koneksi. Ini adalah bagian yang sering dipanaskan, terutama antara dua logam yang berbeda, dan juga pada penampang konduktor yang menyusut karena kotor, longgar, pendektesian hotpsot yang belum optimal, material yang tidak sesuai, overload, dan korosi, oleh karena itu perlunya melakukan kegiatan inspeksi level 2 saat peralatan dalam keadaan berbeban, untuk mengetahui terjadinya Hotspot maka diperlukan pengukuran suhu dengan metode thermovisi, alat yang digunakan adalah SATRIR D300. Selama peralatan beroperasi peralatan gardu induk atau switchgear, yang mana menghantarkan arus listrik akan mengalami pemanasan, yang disebabkan oleh kerugian arus yang mengalir dalam konduktor yang disebabkan oleh hambatan. Dalam tugas akhir ini akan membahas tentang pengukuran titik hotpsot dengan menggunakan metode thermovisi pada gardu induk 150 kV. Menurut standar buku PLN SK DIR 520 2014, hasil pengukuran selisih suhu klem dan konduktor diambil sempel sebanyak 27 sempel dan diketahui 13 sampel dalam keadaan dalam kondisi baik, dan 2 diantara 27 sampel dalam kondisi diukur 1 bulan lagi, yang mana pada 2 sampel tersebut pada Klem CT arah PMT mencapai suhu 67.0 ⁰C dengan arus maksimum yang dicapai 900 ampere dan arus saat thermo sebesar 1100 ampere, pada Klem DS Rel 1 Arah Flybus mencapai suhu sebesar 82.0 ⁰C dengan arus maksimum yang dicapai 900 ampere dan arus saat thermo 1100 ampere.

Substation equipment or substations that are able to conduct current into heat due to current loss due to conductor resistance. Switchgear has terminals and connections. This is a part that is often heated, especially between two different metals, and also in cross-section of the conductor that shrinks due to dirty, loose, suboptimal hotpsot stress, unsuitable material, overload, and corrosion, therefore it is necessary to carry out level 2 inspection activities when the equipment is in a loaded state, to find out the occurrence of Hotspots it is necessary to measure the temperature by the thermovisi method , the tool used is SATRIR D300. During the equipment operation of the substation or switchgear equipment, which conducts electric current will be subjected to heating, which is caused by the loss of current flowing in the conductor caused by resistance. In this final project, we will discuss the measurement of hotpsot points using the thermovisi method at 150 kV substations. According to the standard book PLN SK DIR 520 2014, themeasurement of the difference in the temperature of the clamps and conductors was taken as much as 27 s of a mpel and it was known that 13 sampel was in good condition, and 2 of 27 sampel in conditions measured for another 1 month, which in 2 sampel in the CT Clamps of the PMT direction reached a temperature of 67.0 ⁰C with a maximum current reached 900 amperes and a current when thermo of 1100 amperes, on the Flybus 1 Way Rail DS Clamps reach a temperature of 82.0 ⁰C with a maximum current reached of 900 amperes and a current when thermo 1100 amperes.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Substations, Thermovisi, Hotspots Gardu Induk, Thermovisi, Hotspot
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Apr 2026 02:21
Last Modified: 20 Apr 2026 02:21
URI: https://repository.itpln.ac.id/id/eprint/6410