SAPUTRA, DIKY and handayani, oktaria (2022) STUDI KELAYAKAN PEMUTUS TENAGA (PMT) TEGANGAN MENENGAH 20KV GAS INSULATED SWITCHGEAR (GIS) ABADI GUNA PAPAN. Diploma thesis, ITPLN.
PROYEK AKHIR_DIKY SAPUTRA_201971090_DIKY SAPUTRA.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Pemutus tenaga atau sering disebut dengan PMT adalah adalah suatu komponen terpenting dalam suatu sistem kelistrikan yang berfungsi untuk membuka dan menutup rangkaian jika terdapat arus beban yang besar. Pada umumnya, setiap peralatan distribusi harus dilakukan pemeliharaan baik secara elektris maupun mekainis guna memastikan kelayakan peralatan agar dapat berfungsi dengan baik. PMT 20 kV Penyulang Jala di GIS Abadi Guna sudah operasikan selama 27 tahun, sehingga perlu dilakukan kajian apakah PMT ini layak digunakan atau tidak. Tujuan penelitian ini mengkaji PMT dikatakan masih layak beroperasi dengan acuan metode analisis data hasil pengujian tahanan isolasi, tahanan kontak dan keserempakan PMT masih sesuai dengan SPLN. Hasil dari pengujian tahanan kontak dengan standar VDE (catalogue 228/4) 1 kV = 1 MΩ menunujukan bahwa PMT masih memiliki tahanan isolasi yang baik dengan inilai >20 MΩ, sedangkan tahanan kontak dengan standar IEC 60694 ≤ 50 µΩ menunjukan hasil yang baik dengan inilai resistansi dibawah 50 µΩ. Pada pengujian keserempakan kontak PMT, didapatkan hasil yang baik jika dibandingkan dengan standar SPLN No 52-1 1984 ≤ 120 ms. Dari hasil pengujian yang telah dilakukan menunjukan bahwa PMT pada penyulang Jala masih layak untuk bekerja.
Circuit breaker or often referred to as a PMT is an important component in an electrical system that functions to open and close the circuit if there is a large load current. In general, each distribution equipment must be maintained both electrically and mechainically to ensure the suitability of the equipment to function properly. The CB 20 kV Feeder at GIS Abadi Guna has been operating for 27 years, so it is necessary to study whether this CB is still suitable for use or not. The CB is said to be still feasible to operate with reference to the results of the isolation resistance test, contact resistance and PMT simultaneously in accordance with the SPLN. The results of the contact resistance test with the VDE standard (catalogue 228/4) 1 kV = 1 MΩ show that CB still has good insulation resistance with a value of > 20 MΩ, while the contact resistance with the IEC standard 60694 50 µΩ shows good results with a value of resistance below 50 µΩ. In the PMT contact synchronous test, good results were obtained when compared to the standard SPLN No. 52-1 1984 120 ms. If it is seen from the results of the tests that have been carried out, it can be concluded that the CB on the mesh feeder is still feasible to work.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Circuit Breaker, Testing, Feasible. Pemutus Tenaga, Pengujian, Kelayakan. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 20 Apr 2026 02:47 |
| Last Modified: | 20 Apr 2026 02:47 |