SATTAR, DANI MAULA and christiono, christiono (2022) UJI KARAKTERISTIK KABEL TANAH DENGAN METODE PENGUJIAN TAN DELTA (TD) PADA DUA SEGMEN SALURAN KABEL TEGANGAN MENENGAH AREA MENTENG. Diploma thesis, ITPLN.
PROYEK AKHIR_DANI MAULA SATTAR_201971101_DANI MAULA SATTAR.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Penelitian ini didasarkan atas adanya permasalahan kabel tanah dikarenakan curah hujan tinggi di daerah tertentu terutama area Jakarta Pusat yang mengakibatkan meningkatnya kelembapan tanah sehingga dapat menyebabkan kekuatan dielektrik kabel SKTM mengalami degradasi dan berpotensi menyebabkan gangguan SKTM. Maka dari itu dilakukan metode pengujian Tan Delta sebagai langkah prediktif untuk menganalisa kondisi kesehatan kabel tanah dan metode dini untuk menentukan baik atau buruknya kabel uji. Setelah dilakukan pengujian tan delta didapatkan perolehan data segmen 1 menunjukkan hasil kabel dalam kondisi baik karena nilai rata-rata tan delta di ketiga fasa adalah 1.0, dengan hasil differensialnya adalah 0.0 dan standar deviasi 0.0. Tindak lanjut segmen 1 yaitu berupa pemeliharaan berkala dalam rentang waktu 5 tahun. Kemudian pada segmen 2 perolehan data nilai rata-rata tan delta fasa R 70.6, fasa S 143.9, dan fasa T 83.92. Untuk nilai differensial fasa R 161.7, fasa S 33.7, dan fasa T 135.08. Terakhir data standar deviasi pada fasa R 4.57, fasa S 20.14, dan fasa T 2.43. Dengan hasil yang dibandingkan dengan standar IEEE 400.2-2013 dapat disimpulkan ketiga fasa segmen 2 dalam kondisi buruk dan perlu secepatnya dilakukan tindak lanjut berupa Tes PD dan penggantian kabel.
This research is based on the existence of underground cable problems due to rainfall in certain areas, especially the Central Jakarta area results in an increase in soil moisture that can degrade the dielectric strength of the SKTM and potentially SKTM interference. Therefore, Tan Delta testing method is carried out as a predictive step to analyze the cable health condition and an early method to determine the good/bad of the test cable. After testing tan delta, it was obtained that the acquisition of segment 1 data results were in good condition because the average value of delta tan in all three phases was 1.0, with the differential results being 0.0 and deviation standard 0.0. Action to segment 1 is periodic maintenance of 5 years. Then in segment 2, the data obtained the average value of tan delta phase R 70.6, phase S 143.9, and phase T 83.92. For differential of phase R 161.7, phase S 33.7, and phase T 135.08. Finally, deviation standard at phase R 4.57, phase S 20.14, and phase T 2.43. From IEEE 400.2-2013 standard, it can be concluded that segment 2 is in poor condition and need action as soon as possible of PD Tests and cable replacement.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Tan Delta Testing, Ground Cable, Cable Insulation, Action Pengujian Tan Delta, Kabel Tanah, Isolasi Kabel, Tindak Lanjut |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |