PENGARUH PEMINDAHAN KWH METER TERHADAP NILAI DEVIASI PEMBACAAN ENERGI TRAFO 3 DARI KUBIKEL INCOMING KE PANEL ENERGI RUANG KONTROL DI GI CITRA HABITAT TANGERANG

MARBUN, BRIAN LUTHER and Pahiyanti, Novi Gusti (2022) PENGARUH PEMINDAHAN KWH METER TERHADAP NILAI DEVIASI PEMBACAAN ENERGI TRAFO 3 DARI KUBIKEL INCOMING KE PANEL ENERGI RUANG KONTROL DI GI CITRA HABITAT TANGERANG. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_BRIAN LUTHER MARBUN_201971049_BRIAN LUTHER MARBUN.pdf] Text
PROYEK AKHIR_BRIAN LUTHER MARBUN_201971049_BRIAN LUTHER MARBUN.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Pada penelitian kali ini akan membahas deviasi yang dimana deviasi ini adalah pengukuran eror yang terjadi pada kwh meter yang dimana hasil dari deviasi ini berbentuk persentase. Yang dimna salah satu pengaruh atau penyebab nilai deviasi ini adalah nilai susut, sehingga harus menurunkan susut nya dengan melakukan pemindahan kwh meter dari kubikle incoming ke panel energi ruang control. energi yang dimana pemindahan kwh meter ini menggunakan ukuran penampang kabel dan Panjang kabel yang berbeda, disini akan melihat dan meneliti apa pengaruh dari luas penampang dan panjang kabel terhadap nilai susutnya dan nilai deviasi. Sehingga ketika sudah mendapatkan data deviasi disini akan membandingkan hasil dari kedua kwh meter tersebut. Pengaruh luas penampang kabel 6mm dan dengan jarak 25 meter yang dimana nilai resistansi nya semakin besar yaitu sebesar 7x10-2 ohm dan 4mm dengan jarak 1 meter yang dimana nilai resistansi nya semakin kecil yaitu 4,2x10-3 ohm. Pengaruh pemindahan kwh meter pembanding dari kubikel incoming ke panel energi akan menyebabkan jarak antara kwh meter utama dan kwh meter pembanding akan semakin kecil karena kedua kwh meter tersebut menggunakan CT yang di hubungkan secara seri. Nilai deviasi kwh meter sebelum pemindahan 0,443% dan setelah pemindahan 0,024%. Maka nilai deviasi kwh meter yang di dapat setelah pemindahan kwh meter pembanding akan semakin kecil. Yang dimana data di dapat melakukan pembacaan dan pencatatan pada stand pada kWh meter.

In this study, we will discuss the deviation where this deviation is a measurement of the error that occurs in the kWh meter where the result of this deviation is in the form of a percentage. One of the influences or causes of this deviation value is the value of shrinkage, so it must reduce the shrinkage by transferring the kwh meter from the incoming cubicle to the energy panel of the control room. energy where the transfer of this kwh meter uses different cable cross-sectional sizes and cable lengths, here will see and examine what is the effect of cross-sectional area and cable length on the shrinkage value and deviation value. So when you get the deviation data here, you will compare the results of the two kWh meters. The effect of the cross-sectional area of the cable is 6mm and with a distance of 25 meters where the resistance value is getting bigger, which is 7x10-2 ohms and 4mm with a distance of 1 meter where the resistance value is getting smaller, namely 4.2x10-3 ohms. The effect of moving the comparison kwh meter from the incoming cubicle to the energy panel will cause the distance between the main kwh meter and the comparison kwh meter to be smaller because the two kwh meters use a CT that is connected in series. The deviation value of kwh meter before displacement is 0.443% and after displacement is 0.024%. Then the deviation value of the kwh meter obtained after the transfer of the comparison kwh meter will be smaller. Which is where the data can be read and recorded on the stand on the kWh meter.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Losses, kWh Meter, Deviation susut daya, kwh meter, deviasi
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Apr 2026 03:17
Last Modified: 20 Apr 2026 03:17
URI: https://repository.itpln.ac.id/id/eprint/6421