Abstract

Pemeliharaan gardu distribusi tanpa padam dengan menggunakan box MCCB sebagai metode pemeliharaan yang baru saja diperkenalkan pada tahun 2021 akhir lalu. Dengan metode ini, pelanggan tidak akan merasakan pemadaman listrik ketika proses pemeliharaan gardu distribusi dilakukan karena beban yang dipikul oleh transformator gardu dipindahkan ke transformator Unit Transformator Bergerak (UTB) dengan proses paralel tegangan. Proses paralel tegangan memiliki resiko terhadap peralatan gardu, maka perlu dilakukan pengukuran dan analisa kualitas daya listrik menggunakan alat Power Quality Meter (PQM) pada pemeliharaan gardu distribusi tanpa padam. Pengukuran dilakukan sebanyak tiga tahap yaitu tahap 1 (sebelum proses paralel tegangan), tahap 2 (saat proses paralel tegangan), dan tahap 3 (setelah proses paralel tegangan). Dimana hasil dari pengukuran tiap tahap ini akan dilakukan analisa kualitas daya listrik sehingga dapat diidentifikasi fenomena – fenomena kualitas daya listrik yang muncul pada setiap tahapnya. Berdasarkan hasil analisa kualitas daya listrik yang dilakukan pada gardu PM 334 di wilayah kerja PT. PLN (Persero) UP3 Lenteng Agung dapat diidentifikasi fenomena yang muncul pada tahap 1, 2, dan 3 dengan jumlah pada tahap 1 yaitu 1 fenomena, tahap 2 yaitu 6 fenomena, dan tahap 3 yaitu 1 fenomena. Dari ketiga tahap tersebut, fenomena kualitas daya listrik paling banyak terjadi pada tahap 2.

Maintenance of distribution substations without going out using MCCB boxes as a maintenance method that was just introduced in late 2021. With this method, customers will not feel a power outage when the distribution substation maintenance process is carried out because the load carried by the substation transformer is transferred to the Mobile Transformer Unit (UTB) transformer with a voltage parallel process. The parallel process of voltage has a risk to substation equipment, it is necessary to measure and analyze the quality of electric power using a Power Quality Meter (PQM) tool for maintenance of distribution substations without blackouts. Measurements were carried out in three stages, namely stage 1 (before the voltage parallel process), stage 2 (during the voltage parallel process), and stage 3 (after the voltage parallel process). Where the results of the measurement of each stage will be analyzed for the quality of electric power so that the phenomena of the quality of electric power that appear at each stage can be identified. Based on the results of the analysis of the quality of electrical power conducted at the PM 334 substation in the working area of PT. PLN (Persero) UP3 Lenteng Agung can identify phenomena that appear in stages 1, 2, and 3 with the number in stage 1 being 1 phenomenon, stage 2 being 6 phenomena, and stage 3 being 1 phenomenon. Of the three stages, the phenomenon of electric power quality mostly occurs in stage 2.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Maintenance without blackout, Parallel voltage, Electrical power quality, Distribution, substation Pemeliharaan tanpa padam, Paralel tegangan, Kualitas daya listrik, Gardu Distribusi
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Apr 2026 03:22
Last Modified: 20 Apr 2026 03:22
URI: https://repository.itpln.ac.id/id/eprint/6422

Actions (login required)

View Item
View Item