SAFITRI, BELLA and Erlina, Erlina (2022) SETTING OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) DI CIRCUIT BREAKER OUTGOING (CBO) PADA GI CAWANG BARU DI PT. PLN (PERSERO) UP3 KRAMAT JATI. Diploma thesis, ITPLN.
PROYEK AKHIR_BELLA SAFITRI_201971110_BELLA SAFITRI.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Dalam pendistribusian tenaga listrik, terkadang terdapat gangguan yang tidak dapat dihindari salah satunya gangguan hubung singkat. Pada penyulang Biku GI Cawang Baru terdapat gangguan kabel akibat jointing SKTM dan juga waktu trip yang tidak sesuai setting nya, maka dari itu, dilakukan perhitungan arus hubung singkat dan perhitungan ulang setting relay Over Current Relay (OCR) dan Ground Fault Relay (GFR) yang digunakan sebagai proteksi sistem jaringan, relay ini bekerja terhadap arus lebih, akan bekerja bila arus yang mengalir melebihi nilai setting. Untuk mengetahui setting relay maka dilakukan perhitungan arus gangguan hubung singkat terbesar terjadi pada penyulang Biku gangguan 3 fasa pada jarak 0,859 km sebesar 12638,701 A, sedangkan arus gangguan hubung singkat terkecil pada gangguan 1 fasa pada jarak 8,590 km sebesar 826,878 A. Setting OCR sebelum dengan waktu trip 0,769 detik dan setelah dilakukan perhitungan setting OCR dengan waktu trip 0,331 detik. Untuk data setting GFR sebelum dengan waktu trip 0,763 detik dan setelah dilakukan perhitungan setting GFR didapatkan hasil waktu trip 0,307 detik. Hal ini membuktikan bahwa perlu dilakukan setting ulang pada relay arus lebih dan relay gangguan tanah agar relay bekerja secara selektif dan cepat dalam mengisolir arus gangguan ketika terjadi di panjang jaringan 100% dan agar tidak menyebar ke seluruh sistem sehingga akan mengurangi kerugian atau energi yang tidak terselamatkan.
In the distribution of electric power, there may be disturbances that cannot be avoided, one of which is a short circuit. At the Cawang Baru GI Biku feeder, there are cable disturbances due to SKTM jointing and also travel times that are not in accordance with the settings, therefore, a short circuit current calculation is carried out and a recalculation of the Over Current Relay (OCR) and Ground Fault Relay (GFR) relay settings. used as network system protection, this relay works against overcurrent, will work when the current flows exceeds the setting value. To find out the relay settings, a short-circuit fault current calculation occurs in the Biku field, a 3 phase fault at 0.859 km is 12638.701 A, while a short-circuit fault current at a single-phase fault at a distance of 8,590 km is 826,878 A. Setting the OCR before the trip time is 0.769 seconds and after calculating the OCR setting with a trip time of 0.331 seconds. For setting the GFR data before the trip time is 0.763 seconds and after calculating the GFR setting the trip time is 0.307 seconds. This proves that it is necessary to reset the overcurrent relay and ground fault relay so that the relay works selectively and in isolating fault currents when they occur in 100% network length and so that they do not spread throughout the system so as to reduce losses or unsaved energy.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Protection, Over Current Relay, Ground Fault Relay, Circuit Breaker Outgoing Proteksi, Over Current Relay, Ground Fault Relay, Circuit Breaker Outgoing |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |