SINKRONISASI TRANSFORMATOR GARDU DISTRIBUSI DENGAN MENGGUNAKAN UNIT GARDU BERGERAK METODE PEMELIHARAAN TANPA PADAM TERHADAP SISTEM KEANDALAN JARINGAN DI PT PLN PERSERO AREA UP3 MENTENG

TAMBUNAN, ANANDA NICOLAS PARDAMEAN and Hutajulu, Albert Gifson (2022) SINKRONISASI TRANSFORMATOR GARDU DISTRIBUSI DENGAN MENGGUNAKAN UNIT GARDU BERGERAK METODE PEMELIHARAAN TANPA PADAM TERHADAP SISTEM KEANDALAN JARINGAN DI PT PLN PERSERO AREA UP3 MENTENG. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_ANANDA NICOLAS PARDAMEAN TAMBUNA_ANANDA NICOLAS PARDA.pdf] Text
PROYEK AKHIR_ANANDA NICOLAS PARDAMEAN TAMBUNA_ANANDA NICOLAS PARDA.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Sejalan dengan waktu yang ada peningkatan kebutuhan penggunaan listrik semakin meningkat, maka dari itu penggunaan kapasitas listrik harus sesuai dengan sistem pendistribusian yang tepat agar penyaluran energi listrik dapat tersalurkan dengan baik dan benar. Syarat syarat yang harus dipenuhi dalam sinkroniasi yaitu vektor grub trafo harus sama beserta dengan dayanya, kemudian memastikan perputaran fasa searah jarum jam sehingga dapat dipastikan hubungan antar fasanya sesuai, kemudian memastikan toleransi tegangan penyulang dengan batas toleransi kurang lebih 1 kV dari 20 kV yaitu batas bawah 19 kV dan batas atas 21 kV, kemudian untuk frekuensi batas toleransi kurang lebih 0,2 Hz dari 50 Hz yaitu batas bawah 49,8 Hz dan batas atas 50,2Hz, dan Untuk hasil pengukuran pada panel box sebelum dan sesudah sinkron tidak melewati batas nilai toleransinya yaitu 10% untuk tegangan maksimal dan 5 % untuk tegangan minimal sehingga dapat disimpulkan proses sinkronisasi berjalan sesuai dengan standar pengoperasiannya. Besar nilai tegangan penyulang optimis pada pukul 10.00 yaitu 20,29, kesalah relatif minimal 1,42 % dan kesalahan relatif maksimal 1,45 %, kemudian pada pukul 11.00 yaitu 20,29, kesalah relatif minimal 1,42 % dan kesalahan relatif maksimal 1,45 %, kemudian pada pukul 12.00 yaitu 20,32, kesalah relatif minimal 1,57 % dan kesalahan relatif maksimal 1,6 %. Kemudian untuk toleransi frekuensi penyulang optimis yaitu pada pukul 10.00 yaitu 49,98 Hz, kesalah relatif minimal 0,04 % dan kesalahan relatif maksimal 0,04 %, kemudian pada pukul 11.00 yaitu 50,00 Hz, kesalah relatif minimal 0 % dan kesalahan relatif maksimal 0 %, kemudian pada pukul 12.00 yaitu 49,99 Hz, kesalah relatif minimal 0,2 % dan kesalahan relatif maksimal 0,2 %. Untuk nilai kesalaharan relatif pada pukul 11.00 didapatkan 0 % dikarenakan frekuensinya sesuai atau 50 Hz. Kemudian untuk hasil perhitungan resistansi kabel NYY dan NA2XSEKBY sudah sesuai dengan standar PUIL 2000 yaitu 1 Kilo Volt sama dengan 1 Kilo Ohm sehingga untuk tahanan isolasi kabel yang digunakan pada saat sinkronisasi sudah sesuai dengan standarnya dan Untuk hasil pengukuran pada panel box sebelum dan sesudah sinkron tidak melewati batas nilai toleransinya yaitu 10% untuk tegangan maksimal dan 5 % untuk tegangan minimal sehingga dapat disimpulkan proses sinkronisasi berjalan sesuai dengan standar pengoperasiannya.

In line with the time there is an increase in the need for electricity use, therefore the use of electricity capacity must be in accordance with the right distribution system so that the distribution of electrical energy can be channeled properly and correctly The conditions that must be met in synchronization are that the transformer grub vector must be the same along with its power, then ensure the phase rotation is clockwise so that it can be ensured that the relationship between the phases is appropriate, then ensure the tolerance of the feeder voltage with a tolerance limit of approximately 1 kV from 20 kV, namely the lower limit 19 kV and the upper limit is 21 kV, then for the frequency the tolerance limit is approximately 0.2 Hz from 50 Hz, namely the lower limit of 49.8 Hz and the upper limit of 50.2 Hz, and the measurement results on the panel box before and after synchronization do not exceed the limit. the tolerance value is 10% for the maximum voltage and 5% for the minimum voltage so that it can be concluded that the synchronization process is running according to its operating standards. The value of the optimistic feeder voltage at 10.00 is 20.29, the relative error is at least 1.42% and the maximum relative error is 1.45%, then at 11.00 is 20.29, the relative error is at least 1.42% and the relative error is maximum 1 0.45%, then at 12.00 which is 20.32, the relative error is at least 1.57% and the maximum relative error is 1.6%. Then for the frequency tolerance of the optimistic feeder, namely at 10.00, which is 49.98 Hz, the relative error is at least 0.04% and the maximum relative error is 0.04%, then at 11.00 is 50.00 Hz, the relative error is at least 0% and the relative error is a maximum of 0%, then at 12.00 i.e. 49.99 Hz, a minimum relative error of 0.2% and a maximum relative error of 0.2%. For the relative error value at 11.00, it was obtained 0% because the frequency was appropriate or 50 Hz. Then for the results of the calculation of the resistance of the NYY and NA2XSEKBY cables, it is in accordance with the PUIL 2000 standard, namely 1 Kilo Volt equals 1 Kilo Ohm so that the insulation resistance of the cable used during synchronization is in accordance with the standard and for the measurement results on the panel box before and after synchronization are not exceeds the tolerance value, which is 10% for the maximum voltage and 5% for the minimum voltage so that it can be concluded that the synchronization process is running according to its operating standards.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Tranformator, UGB, Toleransi, Sinkronisas Transformer, UGB, Tolerance, Sync
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Apr 2026 04:14
Last Modified: 20 Apr 2026 04:14
URI: https://repository.itpln.ac.id/id/eprint/6438

Actions (login required)

View Item
View Item