Abstract

Korona adalah fenomena yang terjadi dengan adanya konduktor terionisasi dengan adanya udara. Dikarenakan gangguan ini tidak dapat langsung diidentifikasikan melalui indra manusia, maka gangguan ini dapat dideteksi dengan alat yang bernama Ultra Transient Earth Voltage untuk mendeteksi Partial Discharge dan kelembaban serta alat untuk mendeketsi suhu menggunakan termovision. Dengan kegiatan inspeksi untuk mengetahui hasil ukur dari kubikel, inspeksi dua gardu beton dengan penyulang Berlin di area PT. PLN Bulungan gardu KL 232 dan KB 11. Hasil pengukuran pada kubikel gardu KL 232 yakni partial discharge 23 dB, suhu 27°C dan kelembaban 86%, sedangkan gardu KB11B yakni partial discharge 13 dB, suhu 29°C dan kelembaban 66%, maka bisa medapatkan hasil perhitungan rugi-rugi daya pada setiap gardu, gardu KL232 dengan rugi-rugi daya 7,90 kW dan gardu KB11B dengan rugi-rugi daya 8,24 kW. Untuk menimalisir rugi-rugi daya pada kubikel yang terkena korona bisa dihilangkan dengan mengoptimalkan nilai kelembaban dan suhu di kubikel. Serta menghilangkan korona dengan membersihkan peralatan menggunakan cairan aseton.

Corona is a phenomenon that occurs in the presence of ionized conductors in the presence of air. Because this disorder cannot be directly identified through the human senses, this disturbance can be detected with a device called Ultra Transient Earth Voltage to detect Partial Discharge and humidity and a device to dequencing temperatures using thermovisions. With inspection activities to find out the measuring results of the cubicle, the inspection of two concrete substations with Berlin refiners in the PT area. PLN Bulungan substation KL 232 and KB 11. The measurement results on the kl 232 substation cubicle are partial discharge 23 dB, temperature 27 °C and humidity 86%, while the KB11B substation is partial discharge 13 dB, temperature 29 ° C and humidity 66%, then it can get the results of the calculation of power losses at each substation, KL232 substation with power losses of 7.90 kW and KB11B substations with power losses of 8.24 kW. To minimize power losses in the cubicle affected by corona, it can be eliminated by optimizing the humidity and temperature values in the cubicle. As well as removing the corona by cleaning the equipment using acetone liquid.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Korona, Kelembaban, Suhu, Rugi-rugi Daya, dan Kubikel Corona, Humidity, Temperature, Power Loss, and Cubicle
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Apr 2026 04:47
Last Modified: 20 Apr 2026 04:47
URI: https://repository.itpln.ac.id/id/eprint/6445

Actions (login required)

View Item
View Item