SURI, MUTIARA PRASTUSIA PASHA and Hutajulu, Albert Gifson (2022) PENGUJIAN TAHANAN ISOLASI, TAHANAN KONTAK DAN KEBOCORAN ARUS PADA DULFUR PENYULANG GADUNG GARDU INDUK CAWANG BARU. Diploma thesis, ITPLN.
PROYEK AKHIR MUTIARA PRASTUSIA PASHA SURI 201_MUTIARA PRASTUSIA PA.pdf
Restricted to Registered users only
Download (4MB)
Abstract
Pada Gardu Induk Cawang Baru terdapat gangguan dulfur penyulang Gadung maka dilakukan pengujian tahanan isolasi, tahanan kontak dan kebocoran arus berguna untuk mengetahui nilai tahanan isolasi, tahanan kontak dan kebocoran arus sudah memenuhi standar atau tidak. Jika nilai tahanan isolasi, tahanan kontak dan kebocoran arus berada dibawah standar maka dilakukan perbaikan. Tujuan dilakukan penelitian ini untuk mengetahui prosedur pelaksanaan pengujian tahanan isolasi, tahanan kontak dan kebocoran arus dulfur, untuk mengetahui hasil pengujian sesuai standar atau tidak dan untuk mengetahui cara untuk memperbaiki nilai dari hasil tahanan isolasi, tahanan kontak dan kebocoran arus apabila tidak memenuhi standar. Hasil pengujian tahanan isolasi bergantung dari kebersihan kompartemen, pengujian nilai tahanan isolasi setelah gangguan flashover dan tidak dibersihkan terjadi penurunan nilai tahanan isolasi dibanding saat terjadi gangguan flashover dan pembersihan kompartemen menghasilkan nilai tahanan isolasi lebih baik dan akurat dibanding sebelumnya sebab nilai tahanan isolasi bergantung pada kebersihan permukaan bushing isolator, kelembaban udara di daerah sekitar dan faktor lama umur pada peralatan tersebut. Tahanan isolasi dipengaruhi besarnya kebocoran arus, sehingga apabila penghantar semakin panjang maka tahanan isolasi akan semakin besar. Hasil pengujian arus bocor dibandingkan dengan pedoman toleransi arus bocor, apabila tidak melebihi batas toleransi maka dilakukan penanganan agar sistem kerja tidak terganggu.
At the Cawang Baru Substation there is interference from the Gadung feeder dulfur, then testing the insulation resistance, contact resistance and leakage current is useful to determine the value of insulation resistance, contact resistance and leakage current that meets the standard or not. If the value of insulation resistance, contact resistance and leakage current is below the standard, repairs are carried out. The purpose of this research is to find out the procedure for carrying out the insulation resistance test, contact resistance and leakage current dulfur, to find out whether the test results are in accordance with the standard or not and to find out how to improve the value of the results of insulation resistance, contact resistance and leakage current if it does not meet the standards. The results of the insulation resistance test depend on the cleanliness of the compartment, testing the insulation resistance value after flashover disturbances and not cleaning the insulation resistance value decreases compared to when a flashover disturbance occurs and compartment cleaning produces a better and more accurate insulation resistance value than before because the insulation resistance value depends on the cleanliness of the surface. insulator bushings, humidity in the surrounding area and the longevity of the equipment. Insulation resistance is influenced by the amount of leakage current, so that if the conductor is longer, the insulation resistance will be greater. The results of the leakage current test are compared with the leakage current tolerance guidelines, if it does not exceed the tolerance limit then handling is carried out so that the work system is not disturbed.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | tahanan isolasi, tahanan kontak, kebocoran arus, standar insulation resistance,contact resistance, leakage current, standard |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 20 Apr 2026 06:25 |
| Last Modified: | 20 Apr 2026 06:25 |
| URI: | https://repository.itpln.ac.id/id/eprint/6449 |