EVALUASI CIRCUIT BREAKER OUTGOING (CBO) PADA PENYULANG MAROS DI UP3 MAKASSAR UTARA

APRILIA, FADILAH AYU and Dini, Hasna Satya (2022) EVALUASI CIRCUIT BREAKER OUTGOING (CBO) PADA PENYULANG MAROS DI UP3 MAKASSAR UTARA. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR _ FADILAH AYU APRILIA _ 20197110_FADILAH AYU APRILIA.pdf] Text
PROYEK AKHIR _ FADILAH AYU APRILIA _ 20197110_FADILAH AYU APRILIA.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Pada penyaluran listrik ke pelanggan terdapat beberapa penghambat berupa gangguan yang bisa terjadi secara eksternal ataupun internal, Jika pemadaman akibat gangguan terjadi maka seluruh kegiatan bisa terhenti secara keseluruhan sehingga membuat kerugian yang sangat besar. Agar area pemadaman tidak terlalu luas dan dapat meminimalisasi energi listrik yang tidak tersalurkan, dibutuhkan alat yang dapat mengurangi lokasi pemadaman akibat suatu gangguan. Salah satu upaya untuk mengurangi daerah pemadaman dengan menggunakan CBO (Circuit breaker Outgoing). Pemasangan CBO merupakan upaya yang dilakukan demi peningkatan mutu pelayanan ketersediaan daya listrik ke pelanggan, pada CBO memiliki sistem proteksi sebagai sistem pengamanan dari gangguan tersebut, Dimana penghubung dan pemutus daya secara cepat pada kondisi normal maupun dalam kondisi terdapat gangguan merupakan fungsi utama dari CBO. Penelitian ini bertujuan untuk mengetahui penentuan setting Relay OCR dan mengetahui bagaimana respon relay pada saat terjadi gangguan pada Circuit breaker Outgoing (CBO) Di Penyulang Maros.Metode Analisa yang digunakan pada penelitian ini yaitu metode Analisa dan metode kuantitatif. Hasil perhitungan nilai arus dan waktu kerja rele OCR pada gardu MTU086 yaitu nilai arus sebesar 198,6 A waktu kerjanya 0,182 detik. Hasil simulasi yang dilakukan pada ETAP menunjukkan bahwa nilai setting rele yang direkomendasikan berhasil bekerja mengamankan gangguan pada penyulang Maros sehingga pada saat terjadi gangguan banyaknya gardu padam dapat terminimalisir.

In the distribution of electricity to customers, there are several obstacles in the form of disturbances that can occur externally or internally. If a blackout due to disturbance occurs then all activities can be stopped as a whole, resulting in very large losses. So that the blackout area is not too wide and can minimize the electrical energy that is not channeled, a tool is needed that can reduce the location of the blackout due to a disturbance. One of the efforts to reduce blackout areas is to use CBO (Circuit breaker Outgoing). The installation of CBO is an effort made to improve the quality of service for the availability of electric power to customers, the CBO has a protection system as a security system from the disturbance, where the connector and power breaker quickly under normal conditions and in conditions of disturbance are the main functions of the CBO. This study aims to determine the determination of the OCR and GFR relay settings and to find out how the relay responds when there is a disturbance in the Circuit breaker Outgoing (CBO) in the Maros Feeder. The analytical methods used in this study are analytical methods and quantitative methods. The results of the calculation of the current value and working time of the OCR relay at the MTU086 substation are the current value of 27.96 A, the working time is 0.271 seconds. The results of the simulation carried out on ETAP show that the recommended value of the relay setting works successfully to secure disturbances to the Maros feeder so that when a disturbance occurs, the number of outages can be minimized.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Circuit breaker Outgoing, rele, waktu kerja. Circuit breaker Outgoing, relay , working time.
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Apr 2026 08:17
Last Modified: 20 Apr 2026 08:17
URI: https://repository.itpln.ac.id/id/eprint/6454

Actions (login required)

View Item
View Item