Abstract

Pada Sistem Distribusi Tegangan Rendah ( TR ) Tegangan Rendah, dimana tegangan nominal yang disalurkan 230 Volt. PT.PLN (persero) UP3 Cianjur sebuah perusahaan yang bertempat di jalan di Jl. Dr. Muardi No. 165, Bojongherang, Kec. Cianjur, Kabupaten Cianjur, Jawabarat, yang melayani beberapa ULP diantaranya ULP. Cianjur kota, ULP. Cipanas, ULP. Tanggeng Dengan sering terjadinya drop tegangan yang di akibatkan oleh kabel penghantar yang tidak memenuhi kuat hantar arus, panjang jaringan yang melebihi ketentuan radius maupun beban yang sudah melebihi kapasitas atau over load. Dimana ketentuan drop tegangan yang di izinkan sesuai SPLN T6.001-2013. Pada ujung jaring hanya ±5 % saja, hal tersebut terajadi pada gardu yang mempunyai 4 jurusan dimana pada salahsatu jurusan yaitu jurusan 4 akan mengalami drop tegangan melebihi ±5 %. Sehingga peralatan di pelanggan tidak dapat berfungsi dengan baik, hal ini di akibatkan oleh kecilnya kabel penghantar. Adapun upaya yang dilakukan ini adalah mensimulasikan drop tegangan dengan melakukan perbandingan antara Hasil dari Sofware ETAP dan Pengukuran KWH (kilo watt hour) yang terletak pada ujung jaringan. Untuk mengantisipasi hal tersebut, maka salah satu upaya perbaikan drop tegangan dengan cara mengganti kabel pengahantar ke yang lebih besar, dengan berpedoman pada berapa besar kuat hantar arusnya, dengan adanya pergantian kabel tersebut maka jaringan yang di salurkan pada kabel penghantar akan stabil dan tidak akan terjadi drop tegangan.

In low voltage distribution systems (TR) low voltage, where the nominal voltage is transmitted 230 volts. Pt. PLN (Persero) UP3 Cianjur is a company located on the road on Jl. Dr. Muardi No. 165, Bojongherang, Cianjur District, Cianjur Regency, Jawabarat, which serves several ULPs including ULP. Cianjur city, ULP. Cipanas, ULP. Tanggeng With the frequent occurrence of voltage drops caused by conducting cables that do not meet the current conductivity strength, network lengths that exceed radius provisions or loads that have exceeded capacity or over load. Where the voltage drop provisions are allowed according to SPLN T6.001-2013. At the end of the net, it is only ±5%, it is done at substations that have 4 majors where in one major, namely major 4, it will experience a voltage drop exceeding ±5%.. So that the equipment at the customer cannot function properly, this is caused by the small conduction cable. The effort made is to simulate the voltage drop by comparing the results of the ETAP Software and the KWH Measurement (kilo watt hour) located at the end of the network. To anticipate this, one of the efforts to repair the voltage drop by changing the conducting cable to a larger one, guided by how much the current conductor is strong, with the change of the cable, the network distributed to the conducting cable will be stable and there will be no voltage drop.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Sistem Distribusi, Drop Tegangan, Kawat Penghantar Distribution System, Voltage Drop, Conducting Wire.
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 22 Apr 2026 05:09
Last Modified: 22 Apr 2026 05:09
URI: https://repository.itpln.ac.id/id/eprint/6467

Actions (login required)

View Item
View Item