PENGUJIAN KELAYAKAN MINYAK TRAFO MELALUI UJI BREAKDOWN VOLTAGE DI PT.PLN (PERSERO) PLTU LONTAR

ABSYATAMA, DEA ARIESI and Erlina, Erlina (2022) PENGUJIAN KELAYAKAN MINYAK TRAFO MELALUI UJI BREAKDOWN VOLTAGE DI PT.PLN (PERSERO) PLTU LONTAR. Diploma thesis, ITPLN.

[thumbnail of PROYEK TUGAS AKHIR_DEA ARIESI ABSYATAMA_ 2019_DEA ARIESI ABSYATAMA.pdf] Text
PROYEK TUGAS AKHIR_DEA ARIESI ABSYATAMA_ 2019_DEA ARIESI ABSYATAMA.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Banyak terjadi gangguan pada listrik atau banyak masalah pada saat pendistribusian tenaga listrik, salah satu kegagalan atau permasalahan yang paling sering ditemui pada saat pendistribusian listrik adalah mengenai trafo, karena trafo beroperasi secara terus menerus. Masalah pada trafo terjadi karena kegagalan isolasi minyak trafo yang disebabkan oleh penurunan nilai tegangan tembus. Kegagalan isolasi dapat terjadi karena beberapa faktor termasuk penuaan isolasi, penurunan kekuatan dielektrik, dan tegangan lebih yang mempengaruhi isolasi. Dengan melakukan pengujian tegangan tembus diharapkan menjadi bahan acuan untuk menjaga kinerja atau umur transformator. Pengujian dengan menggunakan Alat uji Breakdown Voltage merek Megger OTS80PB. Kelayakan minyak transformator menggunakan pengujian tegangan tembus sebagai hasil simulasi kelayakan berdasarkan standar internasional untuk meningkatkan kehandalan dalam perawatan transformator daya dalam dunia industri khususnya terhadap pelayanan masyarakat. Dengan tegangan tembus yang semakin besar membuktikan minyak tersebut masih layak pakai. dalam penelitian ini didapat hasil rata rata tegangan tembus pada main tank top 80,3kV/2,5mm, main tank bottom 80,3kV/2,5mm dan tap changer 79,8kV/mm yang sudah sesuai standar uji PLN (SPLN) 49-1/1982 harus memiliki tegangan tembus >40kV/2,5mm.

There are many disturbances in electricity or many problems during the distribution of electricity, one of the most common failures or problems encountered during the distribution of electricity is regarding the transformer, because the transformeroperates continuously. The problem with the transformer occurs because of the failure of the transformer oil insulation caused by a decrease in the breakdown voltage value. Insulation failure can occur due to several factors including aging of the insulation, decreased dielectric strength, and overvoltages affecting the insulation. By testing the breakdown voltage, it is expected to be a reference material to maintain the performanceor life of the transformer. Testing using the Megger OTS80PB Breakdown Voltage Test Equipment. The feasibility of transformer oil uses breakdown voltage testing as a result of feasibility simulations based on international standards to increase reliability in powertransformer maintenance in the industrial world, especially for public services. With a higher breakdown voltage, it proves that the oil is still suitable for use. In this study, the average breakdown voltage on the main tank top was 80.3kV/2.5mm, the main tank bottom was 80.3kV/2.5mm and the tap changer was 79.8kV/mm which was in accordance with the PLN (SPLN) 49-1/1982 must have a breakdown voltage of >40kV/2.5mm.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Minyak Transformator, Pengujian tegangan tembus. Transformer Oil, Testing breakdown voltage.
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 22 Apr 2026 05:19
Last Modified: 22 Apr 2026 05:19
URI: https://repository.itpln.ac.id/id/eprint/6470