Pada sistem pendistribusian tenaga listrik, kualitas pelayanan yang baik tentunya harus selalu diberikan. Salah satu contohnya yaitu memberikan nilai tegangan yang baik kepada pelanggan dan tidak adanya gangguan voltage drop. Berdasarkan SPLN No 1 : 1978, tegangan pelayanan maksimum 5% dan minimumnya 10% dari tegangan nominal ideal jaringan tegangan rendah yaitu 220 Volt. Salah satu lokasi yang mengalami gangguan voltage drop adalah daerah Irigasi Kali Bawah Poris Indah Cipondoh. Berdasarkan hasil analisa yang telah dilakukan oleh petugas divisi jaringan PT PLN UP3 Cikokol, ternyata jatuh tegangan yang terjadi di Daerah Irigasi Kali Bawah Poris Indah Cipondoh diakibatkan oleh jauhnya lokasi tersebut dari gardu CPD 51 yang mensuplai listriknya, jaraknya yaitu 630 meter. Kemudian, daerah disekitaran lokasi tersebut juga memiliki beban-beban yang tinggi dikarenakan banyaknya berdiri pemukiman warga. Oleh karena itu, perlu dilakukannya perbaikan di daerah tersebut dengan menggunakan metode pecah beban ke gardu baru. Metode ini dilakukan dengan cara memindahkan beban di jaringan yang lama ke jaringan yang baru, dimana jaringan yang dipindah yaitu 21 tiang terakhir pada jurusan ini, sehingga beban yang di topang oleh satu jurusan tersebut tidak mengalami voltage drop. Hasil yang didapat setelah melakukan pecah beban yaitu tegangan pada sisi terima naik menjadi di fasa R 220 Volt, fasa S 219 Volt, dan fasa T 220 Volt. Dimana sebelumnya nilai dari tegangan pada sisi terimanya yaitu fasa R 190 Volt, fasa S 192 Volt, dan fasa T 200 Volt.

In the electricity distribution system, good service quality must always be provided. One example is providing a good voltage value to customers and the absence of voltage drop disturbances. Based on SPLN No. 1: 1978, the maximum service voltage is 5% and the minimum is 10% of the ideal nominal voltage of a low-voltage network, which is 220 Volts. One of the locations experiencing voltage drop disturbances is the Kali Bawah Poris Indah Cipondoh Irrigation area. Based on the results of the analysis that has been carried out by the network division officer of PT PLN UP3 Cikokol, it turns out that the voltage drop that occurred in the Kali Bawah Poris Indah Cipondoh Irrigation Area was caused by the distance of the location from the CPD 51 substation that supplies electricity, the distance is 630 meters. Then, the area around the location also has high loads due to the large number of residential settlements. Therefore, it is necessary to repair the area by using the load breaking method to a new substation. This method is done by moving the load on the old network to the new network, where the network that is moved is the last 21 poles in this direction, so that the load supported by one direction does not experience a voltage drop. The results obtained after breaking the load are the voltage on the receiving side increases to 220 Volt R phase, 219 Volt S phase, and 220 Volt T phase. Where previously the value of the voltage on the receiving side was the R phase of 190 Volts, the S phase of 192 Volts, and the T phase of 200 Volts.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Drop Voltage, Pecah beban, Gardu sisip Drop Voltage, Rupture load, Substation insert
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 22 Apr 2026 05:23
Last Modified: 22 Apr 2026 05:23
URI: https://repository.itpln.ac.id/id/eprint/6471

Actions (login required)

View Item
View Item