MANTAWS, WINA DHEA and christiono, christiono (2022) Pengujian Pengaruh Kontaminan Zat Padat Dalam Minyak Transformator Terhadap Tegangan Tembus Untuk Mengetahui Keandalan Transformator. Diploma thesis, ITPLN.
PROYEK AKHIR_WINA DHEA MANTAWS_201971084_WINA DHEA MANTAWS.pdf
Restricted to Registered users only
Download (1MB)
Abstract
Pada penelitian ini dilakukan pengujian terhadap kontaminan dalam minyak transformator. Kontaminan yang diujikan berupa korosi besi dan kertas isolasi. Pengujian dilakukan dengan metode pengujian DBV atau breakdown voltage berdasarkan SPLN 49-1:1982 dan menggunakan alat uji Oil Tester DPA (Discharge Parcial Arching) dengan standar IEC 60 422 2013. Hasil dari penelitian ini menunjukkan bahwa kontaminan zat padat berpengaruh dalam nilai tegangan tembus (breakdown voltage) minyak transformator dengan data hasil pengujian saat diberikan kontaminan korosi besi seberat 100 mg dihasilkan tegangan tembus sebesar 27,8 kV dengan keandalan transformator sebesar 47,7% sedangkan saat berat kontaminanya menjadi 1 gram dihasilkan tegangan tembus sebesar 14,4 kV dengan keandalan transformator sebesar 24,7%. Lain halnya pada saat diberikan kontaminan kertas isolasi seberat 100 mg dihasilkan tegangan tembus sebesar 35,9 kV dengan keandalan transformator sebesar 61,6% sedangkan saat berat kontaminanya menjadi 1 gram dihasilkan tegangan tembus sebesar 23,1 kV dengan keandalan transformator sebesar 39,6%. maka, semakin banyak massa kontaminan yang diberikan akan semakin rendah pula kekuatan minyak transformator dalam menahan tegangan tinggi.
In the study, testing of contaminants in transformer oil was carried out. The contaminants tested were in the form of iron corrosion and insulating paper. The test was carried out by the DBV or breakdown voltage test method based on SPLN 49-1: 1982 and using the Oil Tester DPA(Discharge Parcial Arching) test equipment with IEC 60 422 2013 standard. The results of this study show that solid contaminants have an effect in the breakdown voltage value of transformer oil with the test result data when given iron corrosion contaminants weighing 100 mg, a penetrating voltage of 27.8 kV with a transformer reliability of 47.7% while when the contamina weight becomes 1 gram, a penetrating voltage of 14.4 kV is produced with a transformer reliability of 24.7%. In another case, when given an insulating paper contaminant weighing 100 mg, a penetrating voltage of 35.9 kV was produced with a transformer reliability of 61.6% while when the contamina weight became 1 gram, a penetrating voltage of 23.1 kV was produced with a transformer reliability of 39.6%.. therefore, the more contaminant masses given, the lower the strength of the transformer oil in withstanding high voltages.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Minyak Transformator, Kontaminan, Tegangan Tembus, Kekuatan Dielektrik Transformer, Contaminant, Penetrating Voltage, Dielectric Strength. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 22 Apr 2026 07:17 |
| Last Modified: | 22 Apr 2026 07:17 |
| URI: | https://repository.itpln.ac.id/id/eprint/6479 |