Berdasarkan surat Nomor. 1560/DIS.01.01/C06170000/2021 tentang rekonfigurasi wiring kWh meter kubikel main – spare, bahwa rekonfigurasi ini dilakukan untuk mengatasi kesalahan dalam penginputan data kWh meter dan untuk meningkatkan keakurasian peralatan perhitungan energi. Agar perhitungan energi lebih akurat dan tidak ada lagi kesalahan dalam penginputan data, maka dilakukanlah rekonfigurasi wiring kWh meter sebagaimana didasarkan pada Rekonfigurasi ini dilakukan dengan cara menggunakan metode paralel suplai Current Transformer (CT) yang didasarkan pada Dokumen UP2D IK.SET.KWH tentang Instruksi Kerja Pemasangan Kopel Wiring CT Kubikel Main – Spare. Metode ini dilakukan dengan cara memparalel suplai CT kWh Meter sehingga perhitungan energi listrik yang digunakan beban dapat dihitung oleh satu kWh Meter. Setelah dilakukannya rekonfigurasi wiring CT kWh meter maka diperoleh hasil perhitungan total daya dan energi seluruh penyulang adalah sebesar 41307347.37 kW dan 19994101.48 kWh sedangkan hasil perhitungan total daya dan energi sebelum rekonfigurasi adalah sebesar 41213221.20 kW dan 19982922.97 kWh. Dari hasil tersebut selisih daya sebelum dan sesudah rekonfigurasi sebesar 94126.17 kW sedangkan selisih energi sebesar 11178.51 kWh. Oleh karena itu, berdasarkan selisih tersebut maka dapat disimpulkan bahwa setelah dilakukan rekonfigurasi perhitungan daya dan energi dapat menjadi lebih akurat.
Based on letter No. 1560/DIS.01.01/C06170000/2021 regarding the reconfiguration of wiring kWh meter cubicle main – spare that the reconfiguration is done to overcome errors in inputting kWh meter data and to improve accuracy in energy calculations. In order for the energy calculation to be more accurate and there are no more errors in data input, the kWh meter wiring reconfiguration is carried out as based on this reconfiguration using the Current Transformer (CT) parallel supply method based on the UP2D-IK.SET.KWH Document regarding Instructions Cubicle Main CT Wiring Coupling Work – Spare. This method is carried out by paralleling the supply of CT kWh Meter so that the calculation of the electrical energy used by the load can be calculated by one kWh Meter. After reconfiguring the CT kWh meter wiring, the total power and energy calculation results for all feeders are 41307347.37 kW and 19994101.48 kWh, while the total power and energy calculations before reconfiguration are 41213221.20 kW and 19982922.97 kWh. From these results, the difference in power before and after reconfiguration is 94126.17 kW while the energy difference is 11178.51 kWh. Therefore, based on this difference, it can be concluded that after reconfiguration the power and energy calculations can be more accurate.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Rekonfigurasi, kWh Meter, Kubikel main – spare, Paralel CT. Reconfiguration, kWh Meter, Main – spare cubicle, Parallel CT. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 22 Apr 2026 07:27 |
| Last Modified: | 22 Apr 2026 07:27 |
| URI: | https://repository.itpln.ac.id/id/eprint/6484 |