PENGUJIAN TEGANGAN TEMBUS MINYAK ISOLASI TRANSFORMATOR YANG DIPENGARUHI OLEH KONTAMINAN AIR H2O DAN AIR SUPER O2

PRATIWI, SYAHTY and christiono, christiono (2022) PENGUJIAN TEGANGAN TEMBUS MINYAK ISOLASI TRANSFORMATOR YANG DIPENGARUHI OLEH KONTAMINAN AIR H2O DAN AIR SUPER O2. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_SYAHTY PRATIWI_201971100_SYAHTY PRATIWI.pdf] Text
PROYEK AKHIR_SYAHTY PRATIWI_201971100_SYAHTY PRATIWI.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Dalam pengujian ini bertujuan untuk melihat pengaruh kontaminan air terhadap performance isolator minyak transformator, dengan metode pengujian minyak isolator yang diberi kontaminan air jenis super O2 dan menggunakan alat uji BAUR Oil Tester DPA(Discharge Partial Arching) dimana standar alat uji yang digunakan IEC 60156, dan standar nilai tegangan tembus pada minyak isolasi berdasarkan SPLN 49-1:1982 minyak memiliki nilai tegangan tembus ≥ 30kV/2,5mm. Pada kontaminan air suling yang diberikan sebesar 1ml didapatkan penurunan nilai tegangan tembus 15,4kV atau 31,5%, sedangkan pada jumlah kontaminan yang diberikan sebanyak 2ml hingga 10ml nilai tegangan tembus yang dihasilkan semakin menurun hingga 12,7kV. Nilai tegangan tembus yang didapatkan pada pengujian menggunakan kontaminan super O2 didapatkan penurunan nilai hingga 68%, semakin banyak air yang diberikan pada minyak semakin menurun nilai tegangan tembus dan dielektrik pada minyak isolasinya.

This test aims to see the effect of water contaminants on the performance of transformer oil insulators, with the isolator oil testing method given super O2 type water contaminants and using the BAUR Oil Tester DPA(Discharge Partial Arching) test equipment where the standard test equipment used is IEC 60156, and the standard translucent voltage value in insulating oil based on SPLN 49-1: 1982 oil has a penetrating voltage value of ≥30kV / 2.5mm. In the distilled water contaminants given by 1ml, a decrease in the value of the penetrating voltage of 15.4kV or 31.5% was obtained, while in the number of contaminants given as much as 2ml to 10ml the value of the resulting penetrating voltage decreased to 12,7kV. The value of the penetrating voltage obtained in the test using super O2 contaminants obtained a decrease in value of up to 68%, the more water applied to the oil the more the value of the penetrating voltage and the dielectric in the insulating oil decreased.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Minyak Transformator, Air, Tegangan Tembus Transformer Oil, Water, Translucent Voltage
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 22 Apr 2026 08:01
Last Modified: 22 Apr 2026 08:01
URI: https://repository.itpln.ac.id/id/eprint/6488