ANALISA DEVIASI SISTEM PENGUKURAN ENERGI AKIBAT PERBEDAAN SUPLAI VOLTAGE TRANSFORMER INCOMING DAN OUTGOING GARDU INDUK 20 KV PULOGADUNG

DAMAYANTI, SILVIA and Damiri, Dhami Johar (2022) ANALISA DEVIASI SISTEM PENGUKURAN ENERGI AKIBAT PERBEDAAN SUPLAI VOLTAGE TRANSFORMER INCOMING DAN OUTGOING GARDU INDUK 20 KV PULOGADUNG. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_SILVIA DAMAYANTI_201971071_SILVIA DAMAYANTI.pdf] Text
PROYEK AKHIR_SILVIA DAMAYANTI_201971071_SILVIA DAMAYANTI.pdf
Restricted to Registered users only

Download (15MB)

Abstract

Deviasi sistem pengukuran energi merupakan fenomena perbedaan nilai ukur antara peralatan incoming dengan peralatan outgoing Terdapat beberapa faktor penyebab terjadinya deviasi, salah satunya yaitu akibat penggunaan suplai Voltage Transformer (VT) yang berbeda dengan suplai trafo antara sisi incoming dengan sisi outgoingnya. VT merupakan peralatan untuk mengkonversikan tegangan tinggi menjadi tegangan standar sesuai kebutuhan. Kemungkinan penyebab penggunaan sumber VT yang berbeda tersebut didasari atas posisi atau letak BBVT dari penyulang outgoing terdekat. Hal ini menimbulkan perbedaan perkalian dalam perhitungan daya dan energi yang dilakukan kWh meter. Perbedaan tegangan yang terjadi membuat hasil perkalian energi menjadi tidak sesuai antara incoming dengan outgoingnya. Sebaliknya, bahwa dalam sistem perhitungan daya dan energi, nilai tegangan, arus, dan faktor daya harus berasal dari suplai yang sama. Jika hal ini terus berlanjut dan hasil selisihnya bertambah besar maka deviasi yang terjadi juga akan semakin besar sehingga kerugian yang dialami akan semakin besar. Oleh karena itu, dalam kasus ini diperlukan pengembalian suplai VT dari sisi incoming dengan sisi outgoing yang sesuai dengan suplai trafonya sehingga dari deviasi sebesar 1,5% dapat turun menjadi 0,7% sehingga dengan ini dapat turun menjadi 0,8% dari nilai awal. Untuk itu adanya pengembalian ini tidak akan terjadi perbedaan perkalian dalam perhitungan daya dan energi.

Deviation of the energy measurement system is a phenomenon of differences in measuring values between incoming equipment and outgoing equipment There are several factors that cause deviations, one of which is due to the use of Voltage Transformer (VT) supplies that are different from the transformer supply between the incoming side and the outgoing side. VT is equipment to convert high voltage into standard voltage as needed. The possible cause of using the different VT source is based on the position or location of the BBVT from the nearest outgoing supplier. This gives rise to differences in multiplication in the calculation of power and energy that the kWh meter performs. The difference in voltage that occurs makes the result of energy multiplication incompatible between incoming and outgoing. Conversely, that in the power and energy calculation system, the value of voltage, current, and power factor must come from the same supply. If this continues and the result of the difference increases, the deviation that occurs will also be greater so that the losses experienced will be even greater. Therefore, in this case it is necessary to return the VT supply from the incoming side with the outgoing side corresponding to its transformer supply so that from a deviation of 1.5% it can drop to 0.7% so that with this it can drop to 0.8% from the initial value. For this reason, there will be no difference in multiplication in the calculation of power and energy.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Deviasi, Voltage Transformer (VT), Sistem Pengukuran Energi Deviation, Voltage Transformer (VT), Energy Measurement System
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 23 Apr 2026 01:39
Last Modified: 23 Apr 2026 01:39
URI: https://repository.itpln.ac.id/id/eprint/6493