PERBANDINGAN NILAI BREAK DOWN VOLTAGE MINYAK ISOLASI TRANSFORMATOR TENAGA 2 60 MVA 150/20 kV DENGAN MENGGUNAKAN METODE BREAK DOWN VOLTAGE DI GARDU INDUK LEMBURSITU ULTG SUKABUMI

LESTARI, SITI CANTIKA and Damiri, Dhami Johar (2022) PERBANDINGAN NILAI BREAK DOWN VOLTAGE MINYAK ISOLASI TRANSFORMATOR TENAGA 2 60 MVA 150/20 kV DENGAN MENGGUNAKAN METODE BREAK DOWN VOLTAGE DI GARDU INDUK LEMBURSITU ULTG SUKABUMI. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_SITI CANTIKA LESTARI_201971067_SITI CANTIKA LESTARI.pdf] Text
PROYEK AKHIR_SITI CANTIKA LESTARI_201971067_SITI CANTIKA LESTARI.pdf
Restricted to Registered users only

Download (7MB)

Abstract

Salah satu peralatan listrik tegangan tinggi pada Gardu Induk Lembursitu yaitu transformator tenaga 2 60 MVA 150/20 kV yang berfungsi untuk menyalurkan daya/tenaga dari tegangan tinggi ke tegangan rendah ataupun sebaliknya. Transformator tersebut akan mengalami panas berlebih ketika dioperasikan secara terus menerus, maka dari itu dibutuhkan minyak isolasi sebagai pendingin. Karena seiring dengan berjalannya waktu transformator akan mengalami penurunan kinerja, sehingga perlu dilakukan pemeliharaan, salah satunya dengan melakukan pengujian Break Down Voltage (BDV) minyak isolasi di Gardu Induk Lembursitu dengan menggunakan standar pengujian IEC 60156-1955. Hasil dari pengujian tersebut diketahui bahwa nilai BDV selama dua tahun di Gardu Induk Lembursitu tidak mengalami penurunan, melainkan mengalami peningkatan. Akan tetapi pada tahun 2020 nilai BDV minyak bagian OLTC termasuk dalam kategori buruk, dimana nilai yang dihasilkannya sebesar 29,6 kV, artinya nilai BDVnya di bawah standar yang sudah ditentukan. Karena berdasarkan standar IEC 60422, transformator yang mempunyai tegangan 150 kV harus menghasilkan nilai ≥ 40 kV. Oleh karena itu agar transformator tetap bisa beroperasi dengan baik maka perlu dilakukan penggantian minyak. Dan terbukti setelah dilakukan pengujian ulang pada tahun 2022 nilai BDVnya meningkat sebesar 23,3 kV. Dimana ketika nilai BDV meningkat maka kekuatan dielektrik dari minyak isolasi transformator Gardu Induk Lembursitu pun semakin bagus.

One of the high-voltage electrical equipment at the Overtime Substation is a power transformer 2 60 MVA 150/20 kV which functions to distribute power/power from high voltage to low voltage or vice versa. The transformer will experience excessive heat when operated continuously, therefore insulating oil is needed as a coolant. Because over time the transformer will experience a decrease in performance, so it is necessary to carry out maintenance, one of which is by testing the Break Down Voltage (BDV) insulating oil at the Overtime Substation using the IEC 60156-1955 testing standard. The results of the test show that the BDV value for two years at the Lembursitu Substation did not decrease, but increased. However, in 2020 the BDV value of the OLTC portion of the oil is included in the bad category, where the resulting value is 29.6 kV, meaning that the BDV value is below the predetermined standard. Because according to the IEC 60422 standard, a transformer that has a voltage of 150 kV must produce a value of 40 kV. Therefore, in order for the transformer to continue to operate properly, it is necessary to replace the oil. And it was proven that after retesting in 2022 the BDV value increased by 23,3 kV. Where when the BDV value increases, the dielectric strength of the transformer insulation oil at the Overtime Substation is getting better.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Break Down Voltage, Transformator, Minyak Isolasi Break Down Voltage, Transformer, Insulating Oil
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 23 Apr 2026 01:41
Last Modified: 23 Apr 2026 01:41
URI: https://repository.itpln.ac.id/id/eprint/6494

Actions (login required)

View Item
View Item