PENGUJIAN PEMUTUS TENAGA 150 KV PADA PEMELIHARAAN RUTIN TRAFO 1 DI GARDU INDUK CILEDUG

MULIAWAN, RM RAFLI and Pawenary, Pawenary (2022) PENGUJIAN PEMUTUS TENAGA 150 KV PADA PEMELIHARAAN RUTIN TRAFO 1 DI GARDU INDUK CILEDUG. Diploma thesis, ITPLN.

[thumbnail of Proyek Akhir_RM Rafli Muliawan_201971008_R M. RAFLI MULIAWAN.pdf] Text
Proyek Akhir_RM Rafli Muliawan_201971008_R M. RAFLI MULIAWAN.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Pemutus Tenaga (PMT) merupakan saklar yang digunakan untuk menghubung ataupun memutus hubungan tenaga listrik dalam kondisi wajar ataupun dalam kondisi abnormal maupun gangguan. Untuk senantiasa dapat terpelihara keandalan PMT perlu dilakukan pemeliharaan secara teratur. Penelitian ini bertujuan untuk mengenali prinsip kerja PMT trafo 1, apa saja pengujian yang dilakukan terhadap PMT serta mengenali keandalan dan kelayakan dari Pemutus Tenaga (PMT) tersebut. Pengumpulan data pada penelitian ini menggunakan metode pengumpulan secara langsung, tidak langsung, dan dengan wawancara. Pada analisis penelitian ini memakai data hasil pemeliharaan Pemutus Tenaga (PMT) pada pemeliharaan periode 2 (dua) tahunan ini juga menganalisa pemeliharaan periode sebelumnya tahun 2021 menggunakan metode wawancara. Sedangkan pada 2022 menggunakan metode secara langsung. Metode perhitungan ini dilakukan untuk mendapatkan data hasil pengujian PMT Kemudian melakukan pengolahan data apakah PMT masih layak bekerja dengan baik atau tidak. Dengan acuan metode analisis data hasil menghitung arus bocor pada tahanan isolasi Selama ini pengujian masih sesuai standar yang ditentukan (VDE Catalogue 228) Dari pengujian tahanan isolasi pada PMT sudah melebihi 20 MΩ dan nilai kebocoran arus yang didapat jauh dibawah nilai kebocoran arus yang diizinkan yaitu 1 kV = 1mA. Menunjukan bahwa PMT masih memiliki tahanan isolasi yang baik. Sedangkan Tahanan kontak dan tahanan keserempakan masih sesuai standar dengan standar SPLN 1.1995 – 3.3) ≤ 100 µΩ. Yang menunjukan hasil baik resistansi di bawah 50 µΩ.Sedangkan hasil tahanan pentanahan 2022 sudah sesuai dengan standar yang ditentukan, oleh standar SPLN 1.1995 – 3.3 yaitu kurang dari 1 Ω sehingga PMT yang diuji masih layak untuk beroperasi. Namun jika tidak bisa dipastikan benar-benar 100% untuk terhubung ke bumi,maka pengujian standar dibuat maksimum dari hambatan atau resistan pada kabel grounding ke bumi, yaitu standar dibawah 2 ohm atau dibawah 1 ohm.

Power breaker (PMT) is a switch that is used to connect or disconnect electric power under normal conditions or in abnormal conditions or disturbances. To always be able to maintain the reliability of PMT, it is necessary to carry out regular maintenance. This study aims to identify the working principle of the PMT transformer 1, what tests were carried out on the PMT and to recognize the reliability and feasibility of the Power Breaker (PMT). Collecting data in this study using direct, indirect, and interview methods. In the analysis of this study, using data from the maintenance of Power Breakers (PMT) in the maintenance of this 2 (two) year period, it also analyzes the maintenance of the previous period in 2021 using the interview method. While in 2022 using the direct method. This calculation method is carried out to obtain data from the PMT test results. Then perform data processing whether PMT is still feasible to work well or not. With reference to the data analysis method, the results of calculating the leakage current on the insulation resistance So far, the test is still according to the specified standard (VDE Catalog 228). kV = 1mA. Shows that PMT still has good insulation resistance. Meanwhile, the contact resistance and simultaneous resistance are still in accordance with the standard SPLN 1.1995 – 3.3) 100 . Which shows good results, the resistance is below 50 . While the results of the 2022 ground resistance are in accordance with the standards specified, by the SPLN 1.1995 – 3.3 standard, which is less than 1 so the tested PMT is still feasible to operate. However, if it cannot be ascertained that it is absolutely 100% connected to earth, then the standard test is made for the maximum resistance or resistance in the grounding cable to earth, which is standard below 2 ohms or below 1 ohm.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Pemutus Tenaga (PMT), tahanan pentanahan, tahanan isolasi, tahanan kontak, keserempakan kontak. Power Breakers (PMT), ground resistance, isolation resistance, contact resistance, contact simultaneity.