SYAHBANI, RIFKY NAUFAL and Sukmajati, Sigit (2022) PENGARUH KETIDAKSEIMBANGAN BEBAN TERHADAP ARUS NETRAL DAN SUSUT (LOSSES) PADA TRAFO DISTRIBUSI KT 0040 DI PT.PLN (PERSERO) ULP KOTA PONTIANAK. Diploma thesis, ITPLN.
PROYEK AKHIR_RIFKY NAUFAL SYAHBANI_201971001_RIFKY NAUFAL SYAHBAN.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Dalam memenuhi kebutuhan tenaga listrik tersebut berdasarkan data pada saat pengukuran pemeliharaan terjadi pembagian beban yang tidak merata antar setiap fasanya. Hal ini disebabkan karena pada proses penyambungan baru yang tidak memperhatikan kondisi beban antar fasa pada gardu distribusi tersebut dan terjadi pembagian beban-beban yang pada awalnya merata tetapi karena ketidakserempakan waktu pemakaian atau penyalaan beban-beban tersebut maka menimbulkan ketidakseimbangan beban yang dapat menimbulkan rugi-rugi (losses). Gardu KT0040 berkapasitas 100kVA, penyulang Arteri di PT. PLN (Persero) ULP Kota Pontianak. Dari hasil inspeksi pengukuran didapatkan ketidakseimbangan beban yang berupa ketidakmeratakan beban fasa. Persentase ketidakseimbangan yang dihitung sebesar 71,33%. Langkah selanjutnya meratakan beban dimana fasa R=34A, fasa S=36 A, dan fasa T=37A. dari perhitungan persentase sesudah dilakukan pemerataan beban didapatkan 2,67%. Dari hasil sesudah dilakukan pekerjaan pemerataan selisih dari sebelum dan sesudah 68,66%. Ketidakseimbangan yang tedapat pada Gardu KT 0040 terjadinya susut (losses) akibat adanya arus netral yang mengalir di penghantar netral. Yang dimana nilai rugi-rugi (losses) pada sebelum diseimbangkan 1,24kW menjadi 0,03kW setelah di seimbangkan. Dengan dilakukan dengan metode pemerataan beban dengan cara mengubah jumperan Sambungan Rumah (SR). pemindahan jumperan dari beban pincang fasa R yang besar dibagi ke fasa S dan T. Dilakukan sesudah pemerataan mengukur ulang beban total.
In meeting the electricity demand, based on the data at the time of maintenance measurement, there is an uneven distribution of the load between each phase. This is because the new connection process does not pay attention to the condition of the load between the phases at the distribution substation and the load distribution occurs which is initially evenly distributed but due to the misalignment of the time of use or the ignition of these loads, it causes a load imbalance that can cause losses. (losses). Substation KT0040 with a capacity of 100kVA, Arterial feeder at PT. PLN (Persero) ULP Pontianak City. From the inspection results, it is found that the load imbalance is in the form of an uneven phase load. The calculated imbalance percentage is 71.33%. The next step is to level the load where the R = 34A phase, S = 36 A phase, and T = 37A phase. from the calculation of the percentage after the equalization of the load is obtained 2.67%. From the results after the work of equalizing the difference between before and after 68.66%. The imbalance that occurs at the KT 0040 Substation is the occurrence of losses due to the neutral current flowing in the neutral conductor. Which is where the value of losses before being balanced is 1.24kW to 0.03kW after being balanced. This is done by using the load equalization method by changing the Home Connection (SR) jumper. the transfer of jumpers from the large R phase lame load is divided into S and T phases. It is carried out after equalization and re-measures the total load.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Ketidakseimbangan beban, rugi-rugi, pemerataan beban load imbalance, losses, load distribution |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Apr 2026 01:55 |
| Last Modified: | 23 Apr 2026 01:55 |
| URI: | https://repository.itpln.ac.id/id/eprint/6499 |