PENGATURAN KOORDINASI PROTEKSI PADA TRAFO PENYULANG WAROK GIS KEMBANGAN MENGGUNAKAN OVER CURRENT RELAY (OCR)

NAUFAL, RAFIF ADITYA and Dini, Hasna Satya (2022) PENGATURAN KOORDINASI PROTEKSI PADA TRAFO PENYULANG WAROK GIS KEMBANGAN MENGGUNAKAN OVER CURRENT RELAY (OCR). Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_RAFIF ADITYA NAUFAL_201971146_RAFIF ADITYA NAUFAL.pdf] Text
PROYEK AKHIR_RAFIF ADITYA NAUFAL_201971146_RAFIF ADITYA NAUFAL.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Gardu Induk Kemabangan merupakan sebuah gardu 150 kV. Yang memiliki 3 unit Transformator Tenaga, daya trafo di Gardu Induk Kembangan sebesar 60 MVA. Didalam Gardu terdiri dari beberapa penyulang tegangan menengah yang digunakan untuk pendistribusian menuju ke konsumen. Setiap Gardu Induk setiap penyulang tegangan menengah sering terjadi mengalami gangguan, dianataranya gangguan hubung singkat. Oleh karena itu, untuk menghindari atau meminimalisir gangguan di perlukan sistem proteksi yang memenuhi persyaratan sensitifitas, keandalan, selektifitas dan kecepatan. Peralatan proteksi biasa yang digunakan dalam tegangan menengah ialah rele arus lebih (OCR). Rele ini berfungsi sebagai pengaman atau menginstruksikan PMT/CB untuk membuka, sehingga SUTM/SKTM yang mengalami gangguan dapat dipisahkan dari jaringan. Pada hasil perbandingan pengaturan koordinasi OCR dapat dilihat melalui kurva. Hasil kurva koordinasi dari setting Rele pada sisi incoming di dapat nilai TMS = 0,957 detik dan pada sisi outgoing nilai TMS sebesar 0,621 detik. Koordinasi antar rele pada perhitungan sudah sesuai dengan standart koordinasi dengan CTI sebesar 0,3 - 0,5 detik

The Kemambangan Substation is a 150 kV substation. Which has 3 units of Power Transformers, the transformer power at the Kembangan Substation is 60 MVA. Inside the substation consists of several medium voltage feeders which are used for distribution to consumers. Every substation, every medium voltage feeder, often experiences disturbances, including short circuits. Therefore, to avoid or minimize interference, a protection system that meets the requirements of sensitivity, reliability, selectivity and speed is needed. The usual protective equipment used in medium voltage is the overcurrent relay (OCR). This relay functions as a safety or instructs the PMT/CB to open, so that the SUTM/SKTM that is experiencing interference can be separated from the network. The results of the comparison of OCR coordination settings can be seen through the curve. The results of the coordination curve of the relay setting on the incoming side can be TMS = 0.957 seconds and on the outgoing side the TMS value is 0.621 seconds. The coordination between relays in the calculation is in accordance with the coordination standard with the CTI of 0.3 - 0.5 seconds

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator, Relay, dan Gangguan Hubung Singkat Transformer, Relay and Short Circuit Fault
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 23 Apr 2026 02:24
Last Modified: 23 Apr 2026 02:24
URI: https://repository.itpln.ac.id/id/eprint/6505