Abstract

Kebutuhan energi listrik selalu meningkat dari tahun ke tahun. Permasalahan yang sering terjadi pada distribusi adalah gangguan penyulang. Jika semakin sering padamnya listrik menyebabkan energi tidak tersalurkan dan menyebabkan kerugian PLN. Tujuan penelitian ini untuk mengetahui penurunkan ENS (Energy Not Served) dengan metode inspeksi thermo visual camera. Upaya pendeteksi gangguan yang diakibatkan oleh peralatan Jaringan Tegangan Menengah dapat menggunakan metode alat bantu yaitu Thermo Visual Camera series SATIR D 300. Setelah dilakukan perhitungan data yang diperoleh menggunakan rumus ENS yaitu total keseluruhan, kWh tidak tersalurkan sebelum dilakukan inspeksi thermo visual camera bulan Oktober 295,92 ��ℎ, bulan November 287,1 ��ℎ dan bulan Desember 289,98 � ��ℎ sedangkan setelah dilakukan inspeksi thermo visual camera pada bulan Januari 130,14 ��ℎ, pada Februari 106,74 ��ℎ, bulan Maret 104,94 ��ℎ, bulan April 83,34 ��ℎ dan bulan Mei 42,66 ��ℎ. Dan total keseluruhan, rupiah tidak terselamatkan sebelum dilakukan inspeksi thermo visual camera bulan Oktober �� 427.515,62, bulan November �� 414.773,37 dan bulan Desember �� 418.934,11 sedangkan setelah dilakukan inspeksi thermo visual camera bulan Januari �� 188.232,73, bulan Februari �� 154.207,22, bulan Maret �� 151.606,75, bulan April �� 120.401,29 dan bulan Mei �� 61.850,37. Hal ini membuktikan bahwa metode inspeksi thermo visual camera dapat menyelamatkan kWh dan rupiah.

The need for electrical energy is always increasing from year to year. The problem that often occurs in distribution is feeder interference. If more frequent power outages cause energy not to be channeled and cause PLN losses. The purpose of this study was to determine the reduction of ENS (Energy Not Served) with the inspection method of the thermo visual camera. Efforts to detect disturbances caused by Medium Voltage Network equipment can use the tool method, namely the Thermo Visual Camera series SATIR D 300. After calculating the data obtained using the ENS formula, namely the total, kWh is not distributed before the inspection of the thermo visual camera in October 295, 92 ��ℎ, November 287.1 ��ℎ and December 289.98 ��ℎ while after inspection of the thermo visual camera in January 130.14 ��ℎ, in February 106.74 ��ℎ, March 104.94 ��ℎ, April 83.34 ��ℎ and the month of May 42.66 ��ℎ. And in total, the rupiah was not saved before the inspection of the thermo visual camera in October �� 427,515.62, in November �� 414,773.37 and in December �� 418,934.11 while after the inspection of the thermo visual camera in January �� 188,232.73, in February �� 154,207.22, March �� 151,606.75, April �� 120,401.29 and May �� 61,850.37. This proves that the thermo visual camera inspection method can save kWh and rupiah.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Listrik, Inspeksi, Gangguan, Penyulang Electrician, Inspection, Disturbance, Feeder
Subjects: Skripsi
Bidang Keilmuan > Teknik Tenaga Listrik
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 23 Apr 2026 02:31
Last Modified: 23 Apr 2026 02:31
URI: https://repository.itpln.ac.id/id/eprint/6507

Actions (login required)

View Item
View Item