GHAFUR, NASHUHAN ABDUL and Suyanto, Heri (2022) KOORDINASI SISTEM PROTEKSI DENGAN MENGGUNAKAN RELAY OVER CURRENT RELAY (OCR) DAN GROUND FAULT RELAY (GFR) DI PENYULANG ROSITA PT PLN (Persero) UP3 BANDENGAN. Diploma thesis, ITPLN.
PROYEK AKHIR_NASHUHAN ABDUL GHAFUR_201971070_NASHUHAN ABDUL GHAFU.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Koordinasi sistem proteksi Over Current Relay (OCR) dan Ground Fault Relay (GFR) yang ditempatkan pada bagian incoming di trafo tenaga 150 kV GI Angke dan pada bagian outgoing di penyulang Bandengan 20 kV, dari hasil perhitungan gangguan arus lebih didapat arus gangguan tiga fasa sebesar 13366,13 A, sehingga OCR pada bagian outgoing akan bekerja 0,7 detik, dan OCR incoming akan bekerja 0,639 detik. Sementara gangguan terbesar pada 1 fasa ke tanah sebesar 955,69 A. Dan relai yang akan bekerja mengamankan adalah GFR outgoing dengan waktu kerja 0,688 detik, sementara GFR incoming sebagai back up akan bekerja dengan waktu 0,6755 detik. Alat proteksi sangat diperlukan untuk mengurangi dan mencegah dampak dari gangguan hubung singkat, jika alat proteksi salah dalam memberikan respon maka bisa terjadi trip. Koordinasi proteksi OCR dan GFR yang ditempatkan pada penyulang bawal memiliki tujuan untuk mencegah terjadinya pemadaman total bila terjadi gangguan berupa arus gangguan hubung singkat dan gangguan arus lebih.
Coordination of the Over Current Relay (OCR) and Ground Fault Relay (GFR) protection systems which are placed on the incoming section of the 150 kV GI Angke power transformer and on the outgoing section of the 20 kV Bandengan feeder. 13366,13 A, so that the OCR on the outgoing part will work 0.7 seconds, and the incoming OCR will work 0.639 seconds. Meanwhile, the biggest disturbance in 1 phase to ground is 955.69 A. And the relay that will work securely is the outgoing GFR with a working time of 0.688 seconds, while the incoming GFR as a backup will work with a time of 0.6755 seconds. Protective devices are needed to reduce and prevent the impact of short-circuit faults, if the protective equipment is incorrect in responding, a trip can occur. Coordination of OCR and Ground GFR protection placed on pomfret feeders has the aim of preventing a total blackout in the event of a disturbance in the form of short circuit fault current and over current disturbance.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Proteksi, OCR, GFR, Relai Protection, OCR, GFR, Relay |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Apr 2026 04:33 |
| Last Modified: | 23 Apr 2026 04:33 |
| URI: | https://repository.itpln.ac.id/id/eprint/6515 |