HASANU, MOCHAMAD DAFA and Ispranyoto, Edy (2022) PENGUJIAN PARTIAL DISCHARGE MENGGUNAKAN ULTRA TRANSIENT EARTH VOLTAGE PLUS2 PADA KUBIKEL 20 KV PT PLN (PERSERO) AREA CIKUPA. Diploma thesis, ITPLN.
PROYEK AKHIR_MOCHAMAD DAFA HASANU_201971023_MOCHAMAD DAFA HASANU.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Partial discharge ialah kerusakan yang terjadi pada sebuah isolasi baik itu dipermukaan isolasi tersebut atau didalam sebuah isolasi, jika dibiarkan tanpa adanya tindakan dalam jangka waktu yang lama partial discharge dapat merusak dibagian permukaan maupun didalam sebuah isolasi sehingga akan menyebabkan kegagalan isolasi dan menimbulkan flash over. Dikarenakan gangguan ini tidak dapat langsung diketahui melalui indra manusia, maka gangguan ini dapat dideteksi dengan alat yang bernama Ultra TEV Plus2 (Transient Earth Voltage). Ultra TEV Plus2 merupakan peralatan yang dapat mendeteksi Partial Discharge (PD Detector) dengan bantuan sensor yang nantinya direkam melalui intensitas bunyi desibel (dB) yang berfungsi untuk mendeteksi serta menguji Partial Discharge pada peralatan listrik diantaranya yaitu CT (Current Transformator), PT (Potensial Transformator), Busbar, Load Break Switch, Circuit Breaker, Kabel dll. Penelitian ini dilakukan pada gardu distribusi jenis beton yang dilakukan pengujian menggunakan 6 sampel gardu, yaitu 3 buah gardu terindikasi partial discharge dan 3 buah gardu normal/tidak terdapat indikasi partial discharge. Berdasarkan hasil penelitian ini, proses terjadinya partial discharge cenderung terdapat pada kubikel jenis CBO karena pada kubikel jenis ini terdapat banyak penampang/peralatan-peralatan listrik seperti Trafo CT, Trafo PT, PMT dll.
Partial discharge is damage that occurs in an insulation either on the surface of the insulation or in an insulation, if left without action for a long period of time partial discharge can damage the surface or inside an insulation so that it will cause insulation failure and cause flash over. Because this disturbance cannot be directly detected through the human senses, this disturbance can be detected with a tool called Ultra TEV Plus2 (Transient Earth Voltage). Ultra TEV Plus2 is an equipment that can detect Partial Discharge (PD Detector) with the help of sensors which will be recorded through decibel sound intensity (dB) which serves to detect and test Partial Discharge on electrical equipment including CT (Current Transformer), PT (Potensial Transformer). Busbar, Load Break Switch, Circuit Breaker, Cable etc. This research was conducted at distribution substations of the type of concrete that were tested using 6 samples of substations, namely 3 substations with partial discharge indication and 3 normal substations/no partial discharge indication. Based on the results of this study, the process of partial discharge tends to occur in CBO type cubicles because in this type of cubicle there are many cross sections/electrical equipment such as CT transformer, PT transformer, PMT etc.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Partial Discharge, UltraTEV, MV Cells Partial Discharge, UltraTEV, MV Cells |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Tenaga Listrik |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 24 Apr 2026 05:06 |
| Last Modified: | 24 Apr 2026 05:06 |
| URI: | https://repository.itpln.ac.id/id/eprint/6526 |