STUDI KASUS KERUSAKAN REGULATOR TEKANANALIRAN GAS PADA MATERING REGULATING STATION UNTUK SPBG DAAN MOGOT PT PGN SOLUTION AREA JAKARTA

SIEKELTA, TIMOTIUS and Sulistiyo, Eko (2019) STUDI KASUS KERUSAKAN REGULATOR TEKANANALIRAN GAS PADA MATERING REGULATING STATION UNTUK SPBG DAAN MOGOT PT PGN SOLUTION AREA JAKARTA. Diploma thesis, ITPLN.

[thumbnail of timotius 2016-72-022.pdf] Text
timotius 2016-72-022.pdf
Restricted to Registered users only

Download (5MB)

Abstract

Salah satu cara menyalurkan gas dari stasiun gas (offtake) ke konsumen yaitu dengan melewati matering regulating station. Pada matering regulating station terdapat komponen-komponen dasar antara lain gas filter, relief valve, check valve, pressure gauge, regulator, safety shut off valve. Regulator sangat berperan dalam penyaluran gas ke konsumen.hal ini jika regulator tidak bekerja dengan baik dapat berdampak kerugian dan tidak memuaskan konsumen.hsl ini dapat dilihat jika regulator terjadi kerusakan dapat dilihat pada hasil peyaluran tekanan aliran pada tanggal 19/04/2019 pada jam 08:00 sampai 17:00 tekanan gas pada saat itu naik hingga 9,0189 bar. Dimana hal ini merupakan salah satu penyebab terjadinya kerusakan pada regulator adalah filter gas kotor, adanya tekanan balik ke regulator, dan ,membran pada regulator bocor. Hal ini yang membuat tekanan yang disalurkan MR/S (matering regulating station) SPBG Daan Mogot meningkat atau tidak sesuai dengan pengaturan yang sudah ditetapkan pada MR/S teersebut. Oleh karena itu dilakukan upaya penanggulangan dengan cara memperbaiki regulatornya sehingga aliran gas ke konsumen dapat stabil kembali.

One way to deliver gas from the gas station (offtake) to consumers is by passing the matering regulating station. At the matering regulating station there are basic components including a gas filter, relief valve, check valve, pressure gauge, regulator, safety shut off valve. Regulators play a very important role in the distribution of gas to consumers. If the regulator does not work well, it can cause loss and not satisfy the consumer. This can be seen if the regulator is damaged. 8:00 to 17:00 gas pressure at that time rises to 9.0189 bar. Where this is one of the causes of damage to the regulator is a dirty gas filter, the back pressure to the regulator, and, the membrane on the regulator is leaking. This makes the pressure channeled by the MR / S (matering regulating station) of Daan Mogot SPBG increase or not in accordance with the regulations set forth in the MR / S. Therefore, countermeasures are made by improving the regulator so that gas flow to consumers can be stable again.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Metering Regulating Station, Regulator, Tekanan Gas Metering Regulating Station, Regulator, Gas Flow
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknik Mesin
Depositing User: Sudarman
Date Deposited: 14 May 2026 06:12
Last Modified: 14 May 2026 06:12
URI: https://repository.itpln.ac.id/id/eprint/6721

Actions (login required)