ANALISIS PENGARUH PERBEDAAN SUHU AIR PENDINGIN KONDENSOR TERHADAP EFEKTIFITAS KONDENSOR 3A DI PLTU UNIT 3 PT PJB UP GRESIK

Shurur, Mohammad Shahrus and Rusjdi, Halim (2019) ANALISIS PENGARUH PERBEDAAN SUHU AIR PENDINGIN KONDENSOR TERHADAP EFEKTIFITAS KONDENSOR 3A DI PLTU UNIT 3 PT PJB UP GRESIK. Diploma thesis, ITPLN.

[thumbnail of Proyek Akhir  M Shahrus Shurur-dikonversi (1).pdf] Text
Proyek Akhir M Shahrus Shurur-dikonversi (1).pdf
Restricted to Registered users only

Download (1MB)

Abstract

Jika air pendingin yang bersirkulasi cukup rendah, akan menimbulkan tekanan balik yang rendah untuk membuang uap keluar dari turbin. Hal ini akan menurunkan tekanan akhir yang keluar dari turbin sehingga daya turbin akan menjadi lebih besar dibandingkan dengan instalasi yang tidak meggunakan kondensor. Atau dengan daya turbin yang tetap, efisiensi instalsi akan meningkat. Kondensor uap yang merupakan alat penukar kalor berpendingin air akan sangat dipengaruhi oleh kondisi air pendingin atau sirkulasi, baik suhu atau kebersihannya. Pada pembuatan tulisan ini akan diperhitungkan pengaruh dari perbedaan suhu air pendingin terhadap unjuk kerja kondensor sehingga mempengaruhi efisien dari unit itu sendiri. Pengukuran diambil berdasarkan data-data yang didapat dari ruang rendal OP PLTU. Parameter yang diukur yaitu suhu air laut, tekanan kondensor, kevakuman kondensor . Hasil akhir diduga bahwa dengan sernakin tingginya suhu air pendingin, maka akan meningkatkan kevakuman kondensor,Laju Perpindahan Panas serta menurunkan efektifitas kondensor. Pelaksanaan dilakukan pada tanggal 13 otober 2018 pukul 09.45 dan pada tanggal 14 Desember 2018 pada pukul 13.30 didapatkan hasil Pada Suhu air laut sebesar 31.39° C memiliki nilai efektifitas yang lebih tinggi yaitu sebesar 0.99601,nilai kevakuman yang lebih rendah 0.0942 bar,nilai laju perpindahan panas sebesar 10.31464 MW. Sedangkan pada suhu 33.767°C menghasilkan nilai vakum sebesar 0.107647 bar, Laju perpindahan panas 153.60124, efektifitas sebesar 0.96601

If the circulating cooling water is low enough, it will cause low back pressure to throw steam out of the turbine. This will reduce the final pressure coming out of the turbine so that the turbine power will be greater compared to installations that do not use a condenser. Or with a fixed turbine power, installation efficiency will increase. Steam condenser which is a water-cooled heat exchanger will be greatly influenced by the condition of cooling water or circulation, both temperature or cleanliness. In making this paper will be taken into account the effect of the difference in the temperature of the cooling water on the performance of the condenser so that it affects the efficiency of the unit itself. Measurements were taken based on data obtained from the OP PLTU rendal room. The parameters measured are sea water temperature, condenser pressure, vacuum condenser. The final result is expected that with the high temperature of the cooling water, it will increase the condenser vacuum, heat transfer rate and reduce the effectiveness of the condenser. The implementation was carried out on 13 October 2018 at 09:45 and on 14 December 2018 at 13.30 the results obtained at sea water temperature of 31.39 ° C had a higher effectiveness value of 0.99601, a lower vacuum value of 0.0942 bar, the value of heat transfer rate amounting to 10,31464 MW. While at a temperature of 33,767 ° C produces a vacuum value of 0.107647 bar, heat transfer rate of 153.60124, effectiveness of 0.96601

Item Type: Thesis (Diploma)
Uncontrolled Keywords: kondensor, beda suhu, effisiensi thermal condenser, temperature difference, thermal efficiency
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknik Mesin
Depositing User: Sudarman
Date Deposited: 14 May 2026 06:15
Last Modified: 14 May 2026 06:15
URI: https://repository.itpln.ac.id/id/eprint/6722