ANALISIS PENGARUH EFEKTIVITAS TERHADAP TEKANAN VAKUM KONDENSOR UNIT 1 DAN UNIT 2 SEBELUM DAN SESUDAH PERAWATAN DI PLTGU KERAMASAN

SANTOSO, ANDREAS BUDI and alfalah, win (2020) ANALISIS PENGARUH EFEKTIVITAS TERHADAP TEKANAN VAKUM KONDENSOR UNIT 1 DAN UNIT 2 SEBELUM DAN SESUDAH PERAWATAN DI PLTGU KERAMASAN. Diploma thesis, ITPLN.

[thumbnail of Proyek Akhir Andreas Budi Santoso fix-dikonversi.pdf] Text
Proyek Akhir Andreas Budi Santoso fix-dikonversi.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Kondensor merupakan suatu alat perpindahan panas utama yang berada pada PLTGU Keramasan. Kondensor berfungsi untuk mengkondensasikan uap bekas dari low pressure turbine menjadi air kondensat. Air kondensat akan digunakan kembali sebagai air pengisi boiler. Kondensor merupakan komponen utama yang menjadi penyebab terbesar terjadinya losses pada siklus dan dapat mempengaruhi efektivitas suatu pembangkit. Pendinginan air kondesat terjadi pada kondensor, uap dari sistem gas turbin turun ke kondensor dan didinginkan dengan air yang dipompakan dengan Circulating water pumps. Mengingat pentingnya suatu kondensor dalam unit, maka perlu diketahui seberapa besarkah laju perpindahan panas dan efektivitas kondensor yang optimal. Dilihat dari varisasi tekanan vakum yang ada. Metode yang digunakan untuk analisis pengaruh tekanan vakum terhadap laju perpindahan panas dan efektivitas. Yang pertama mengambil parameter dari central control room, kedua mengumpulkan data yang berhubungan dengan tinjauan literatur, ketiga melakukan perhitungan dasar metode LMTD, dari perhitungan metode LMTD akan didapatkan nilai efektivitas dari kondensor. Adapun tujuan dari penelitian ini adalah mengetahui pengaruh tekanan vakum terhadap efektivitas kondensor unit 1 yang sudah dibersihkan dan unit 2 yang belum dibersihkan. Perbandingan ini dilakukan agar kondensor dapat terjaga dengan baik untuk menghindari kerusakan.

The condenser is a device that replaces heat that is present in Keramasan PLTGU. The condenser works to condense used steam from a low-pressure turbine to air condensate. Condensate water will be reused as boiler fill water. The condenser is the main component that causes the biggest losses in the cycle and can increase generator effectivity. Condensate water cooling occurs in the condenser, steam from the gas turbine system descends to the condenser and is cooled with water pumped with circulating water pumps. Given the importance of a condenser in the unit, it is necessary to consider the optimal displacement and optimal condensation. Judging from the varization of existing vacuum pressure. The method used for the analysis of the influence of the ratio of heat transfer and compatibility. Which takes the first parameter from the central control room, the second collection of data relating to the collection of literature, performs the basic calculation of the method LMTD, from the calculation of the method LMTD the calculation value of the condenser will be obtained. The purpose of this study is an understanding of the pressure on condensation unit 1 that has been cleaned and unit 2 that has not been cleaned. This comparison is done so that the condenser can be repaired properly to prevent damage.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTGU, Tekanan Vakum, Efektivitas Kondensor, air, Pendingin PLTGU, vacuum pressure, Condensor Effectivity, water, cooler
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknik Mesin
Depositing User: Sudarman
Date Deposited: 14 May 2026 06:55
Last Modified: 14 May 2026 06:55
URI: https://repository.itpln.ac.id/id/eprint/6733