Abstract

Kondensor Pembangkit Listrik Tenaga Gas Uap (PLTGU) Cilegon adalah alat penukar kalor yang menggunakan air laut sebagai fluida pendingin yang digunakan untuk mengkondensasikan uap keluaran turbin uap tekanan rendah (low pressure steam turbin). Air laut yang digunakan sebagai fluida pendingin diproses pemurnian terlebih dahulu untuk memisahkan air laut dengan biota laut, akan tetapi dikarenakan biota laut serta sampah-sampah yang berukuran kecil terkadang lolos dari proses pemurnian sehingga mengganggu kebersihan didalam pipa-pipa (tubes), suction pipe dan water box kondensor, mengakibatkan proses perpindahan panas menjadi tidak maksimal dan kinerja dari kondensor akan menjadi berkurang. Untuk mengatasi masalah pengotoran pada kondensor perlu dilaksanakan proses overhaul (proses pengecekan dan pembersihan) pada kondensor PLTGU Cilegon yang dilakukan pada bagian bagian seperti water box, suction pipe, dan pipa-pipa (tube). Hasil dari proses overhaul didapatkan peningkatan pada kireja kondensor PLTGU yang awalnya rata-rata pada uap ekstrasi 37˚C menjadi 35˚C dan pada sisi out 35,89˚C kondensor setelah dilakukan overhaul menjadi 35˚C, dari hasil perhitungan pada data di dapatkan bahwa faktor-faktor yang mempengaruhi kinerja kondensor antara lain faktor kebersihan dari saluran suction pipe, pipa pipa (tube) dan waterbox.

The Cilegon Steam Gas Power Plant (PLTGU) condenser is a heat exchanger that uses seawater as a cooling fluid used to condense the output of low pressure steam turbines. Seawater used as a cooling fluid is purified in advance to separate seawater from marine biota, but due to marine biota and small sized debris sometimes escapes from the purification process so that it interferes with cleanliness in the pipes, tubes, suction pipes and condenser water box, resulting in the process of heat transfer is not optimal and the performance of the condenser will be reduced. To overcome the problem of fouling on the condenser it is necessary to carry out an overhaul process (checking and cleaning process) on the Cilegon power plant condenser which is carried out on parts such as water boxes, suction pipes, and pipes (tubes). The results of the overhaul process showed an increase in the performance of the PLTGU condenser which was originally averaged in the extraction vapor 37 ° C to 35 ° C and on the out side 35.89 ° C the condenser after overhaul to 35 ° C, from the results of calculations on the data obtained that the factors that influence the performance of the condenser include the cleanliness factors of the suction pipe channel, pipes and tube water.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTGU, Kondensor, Overhaul, LMTD PLTGU, Condenser, Overhaul, LMTD
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknik Mesin
Depositing User: Sudarman
Date Deposited: 14 May 2026 07:26
Last Modified: 14 May 2026 07:26
URI: https://repository.itpln.ac.id/id/eprint/6742

Actions (login required)

View Item
View Item