Salah satu komponen utama pada PLTP Kamojang yaitu kondensor. Kondensor pada PLTP ini berjenis kontak langsung dimana air pendingin akan di spray melalui nozzle dan langsung bersinggungan dengan uap bekas turbin. Dihitung dari hasil perhitungan yang sudah diperoleh hasil efektivitas kondensor sangat mempengarui efesiensi dari suatu pembangkit listrik panas bumi Kamojang sebesar 0,98 atau setara daya optimal 53,6 MW. Berdasarkan evaluasi yang dilakukan effektivitas dari kondensor unit 2 didapatkan nilai effektivitas terbaik pada beban 53,6 MW yaitu 0,98. Sedangkan nilai effektivitas terendah di dapatkan pada beban 54,1 MW dan 54,9 MW dengan nilai effektivitas yang didapat yaitu 0,95. Tekanan vakuum pada kondensor sangat mempengaruhi kerja kondensor. Semakin tinggi nilai tekanan vakuum maka akan semakin rendah nilai effektivitas kondensor tersebut,yang dimana dari hasil evaluasi didapatkan pada beban 53,6 MW dengan nilai effektivitas 0,98 tekanan vakuum yang di dapat 127 mbar sedangkan pada beban 54,1 MW dengan nilai effektivitas 0,95 tekanan vakuum yang didapat 134 mbar. Hal-hal yang dapat mengganggu kinerja kondensor adalah temperatur air pendingin, tekanan vakuum kondensor, aliran air pendingin, non condensable gas, dan level air kondensor yang harus dijaga level airnya pada batas NWL. Maka dari itu performa cooling tower dan kinerja dari steam ejector harus selasu di perhatikan.

One of the main components in Kamojang PLTP is condenser. The condenser in the PLTP is a direct contact type where the cooling water will be sprayed through the nozzle and directly in contact with the turbine steam. Calculated from the results of the calculations that have been produced condenser results strongly affect the efficiency of a geothermal power plant Kamojang of 0.98 or the equivalent of 53.6 MW optimal power. Based on the evaluation of effectivity of condenser unit 2, the best effectiveness value at 53.6 MW is 0.98. While the cheapest in get at 54.1 MW and 54.9 MW with the effectiveness value is 0.95. Vacuum pressure on the condenser greatly affects the work of the condenser. The higher the vacuum pressure level, the lower the condenser efficiency, which is from the evaluation at 53.6 MW with the effectiveness value of 0.98 vacuum pressure which can be 127 mbarakang at 54.1 MW with an effectivity value of 0.95 vacuum pressure gained 134 mbar. Matters that may interfere with the performance of the condenser are the temperature of the air conditioner, the vacuum condenser pressure, the cooling water flow, the non-condensing gas, and the level of the air condenser that must be maintained at the water level of the NWL boundary. Therefore the performance of the cooling tower and the performance of the steam ejector should be observed.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Efektivitas Kondensor, Tekanan Vakuum, Kinerja Kondensor, PLTP Kamojang. Condenser Effectivity, Vacuum Pressure, Condenser Performance,PLTP Kamojang.
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknik Mesin
Depositing User: Sudarman
Date Deposited: 14 May 2026 07:58
Last Modified: 14 May 2026 07:58
URI: https://repository.itpln.ac.id/id/eprint/6747

Actions (login required)

View Item
View Item