PENGARUH PLUGGING PIPA KONDENSOR UNIT 3 PLTU BANTEN 3 LONTAR TERHADAP NILAI LMTD

RONALDO, OKTA ZIKO and alfalah, win (2021) PENGARUH PLUGGING PIPA KONDENSOR UNIT 3 PLTU BANTEN 3 LONTAR TERHADAP NILAI LMTD. Diploma thesis, ITPLN.

[thumbnail of OKTA ZIKO RONALDO(201772024) (2).pdf] Text
OKTA ZIKO RONALDO(201772024) (2).pdf
Restricted to Registered users only

Download (5MB)

Abstract

Kondensor merupakan sebuah alat yang penting dalam sebuah pembangkit listrik tenaga uap yang berfungsi mengubah uap bekas dari tubin menjadi air kondensate. Agar kinerja kondensor pada pembangkit listrik tenaga uap tetap terjaga maka perludilakukan pemeliharan.Pemeliharan yang di lakukan pada PLTU Banten 3 Lontar ini merupakan pemeliharaan tidak rutin yaitu overhaul. Overhaul pada PLTU Benten 3 Lontar ini dilaksanakan 1 Tahun sekalai. kegiatan overhaul yang di lakukan pada PLTU Banten 3 Lontar pada kondensor meliputi pengeplugkan pipa kondensor yang mengalami perubahan ketebelan pipa yang bertujuan agar tidak terjadinya kebocoran pipa saat sirkulasi air pendingin maka dilakukan pengeplugkan. Pada hasil perhitungan nilai lmtd sebelum pengeplugkan di dapat sebesar 28,22 pengeplugkan pipa kondensor di dapat nilai 29,38 sedangkan setelah yang dimana hanya mengalami kenaikan sebesar 1,16 . Menurut teori LMTD seharusnya setelah di plugging mengalami penurunan di karenakan berkurangnya luas perpindahan panas untuk proses kondensasi.selain itu di sebabkan oleh faktor temperatur inlet uap dan air pendingin tidak akan selalu sama dan jugan di pengarhui suhu lingkungan kondensor.

The condenser is an important tool in a steam power plant which functions to convert used steam from tubins into condensate water. In order for the condenser performance in the steam power plant to be maintained, maintenance is needed. The maintenance carried out at PLTU Banten 3 Lontar is non-routine maintenance, namely overhaul. The overhaul at PLTU Benten 3 Lontar is carried out once a year. Overhaul activities carried out at PLTU Banten 3 Lontar on the condenser include plugging tube The condenser which changes to the thickness of the tube which aims to prevent leakage of the pipe during cooling water circulation is carried out plugging. On the results of the calculation of the value of lmtd before at plugging in the amount of 28,22 condenser got a value of 29,38 while after the plugging tube wich onliy increased by 1,16 . According to the LMTD theory, after plugging it should have decreased due to the reduced area of heat transfer for the condensation process. In addition, it is caused by the inlet temperature factor of the steam and cooling water which will not always be the same and it also affects the condenser ambient temperature.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: plug, Kondensor, LMTD, Kinerja. plug, condenser, LMTD, Performance.
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknik Mesin
Depositing User: Sudarman
Date Deposited: 14 May 2026 13:57
Last Modified: 14 May 2026 13:57
URI: https://repository.itpln.ac.id/id/eprint/6763

Actions (login required)

View Item
View Item