Abstract

UP3 Mempawah menghadapi tantangan besar dalam memastikan keandalan penyaluran listrik di topografi yang beragam, seperti hutan, perbukitan, pesisir, perkebunan, dan kawasan padat penduduk. Penelitian ini fokus pada ULP Tanjung Raya, khususnya penyulang OG Korek dan section AR Ret-ret, yang sering mengalami gangguan akibat petir. Antara April dan Juni, petir menyebabkan 61% dari 28 gangguan, dengan tren yang meningkat. Untuk mengatasi masalah ini, dipasang Current Limiting Device (CLD) pada penyulang OG Korek. Untuk mengatasi gangguan listrik akibat petir, UP3 Mempawah menerapkan solusi dengan pemasangan CLD pada penyulang OG Korek. Sebelum pemasangan CLD, terdapat gangguan sebanyak 17 kali dalam rentang waktu April hingga Juni. Setelah pemasangan, tidak terjadi gangguan listrik akibat petir pada bulan Juli hingga 10 Agustus. Pemasangan CLD mengurangi Energy Not Supplied (ENS) sebesar 245,49 kWh atau setara dengan Rp 353.677,-, serta meningkatkan daya tersalurkan sebesar Rp 340.192,-.

A physical state that results in a device or electrical distribution system failing is called a disturbance. Temporary or lasting disruptions are both possible. Ensuring the dependability of energy distribution in a variety of topographies, including woods, hills, coasts, plantations, and highly inhabited areas, presents major issues for UP3 Mempawah. This study focuses on ULP Tanjung Raya, particularly the AR Ret-ret segment and the OG Korek feeder, which are regularly disrupted by lightning. Of the 28 disturbances, 61% were triggered by lightning between April and June, with an increasing tendency. A Current Limiting Device (CLD) was added to the original Korek feeder in order to solve this problem. In order to mitigate lightning-induced electrical disruptions, UP3 Mempawah installed a Current Limiting Device (CLD) on.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Current Limiting Device (CLD) Current Limiting Device (CLD)
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 07 Jul 2026 10:32
Last Modified: 07 Jul 2026 10:32
URI: https://repository.itpln.ac.id/id/eprint/6837

Actions (login required)

View Item
View Item