PERBANDINGAN KINERJA XGBOOST DAN RANDOM FOREST DALAM ESTIMASI DAYA PLTS APUNG BERDASARKAN PARAMETER CUACA

Laksono, Tarissa Nurhapsari and Haris, Abdul (2026) PERBANDINGAN KINERJA XGBOOST DAN RANDOM FOREST DALAM ESTIMASI DAYA PLTS APUNG BERDASARKAN PARAMETER CUACA. Diploma thesis, Institut Teknologi PLN.

[thumbnail of cover.pdf] Text
cover.pdf

Download (139kB)
[thumbnail of Lembar Pengesahan.pdf] Text
Lembar Pengesahan.pdf

Download (629kB)
[thumbnail of Abstrak.pdf] Text
Abstrak.pdf

Download (195kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (217kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (988kB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of BAB V KESIMPULAN.pdf] Text
BAB V KESIMPULAN.pdf
Restricted to Registered users only

Download (145kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (175kB)
[thumbnail of 202231086_Tarissa Nurhapsari Laksono_Revisi_Skripsi.pdf] Text
202231086_Tarissa Nurhapsari Laksono_Revisi_Skripsi.pdf
Restricted to Registered users only

Download (5MB)

Abstract

Pembangkit Listrik Tenaga Surya (PLTS) Apung memiliki karakteristik iklim mikro yang berbeda dari instalasi darat karena pengaruh permukaan air, sehingga estimasi daya keluarannya memerlukan pendekatan yang mampu menangani hubungan non-linear antarparameter cuaca. Penelitian ini bertujuan membangun dan membandingkan kinerja algoritma Random Forest dan Extreme Gradient Boosting (XGBoost) dalam mengestimasi daya keluaran PLTS Apung berdasarkan suhu, kelembapan, dan intensitas cahaya, serta mengidentifikasi parameter yang paling dominan. Data primer diperoleh melalui sistem akuisisi berbasis Internet of Things pada PLTS Apung Danau Institut Teknologi PLN selama periode 11 sampai 19 Juni 2026 menggunakan sensor DHT22, sensor BH1750, dan modul PZEM-017 DC. Dari 6.293 baris data mentah, diperoleh 3.123 baris data siang hari setelah melalui tahap pembersihan, interpolasi, dan imputasi berbasis kemiripan intensitas cahaya, dengan target daya dihitung dari perkalian tegangan dan arus. Seluruh variabel dinormalisasi menggunakan metode Min-Max, sedangkan nilai hyperparameter ditetapkan sebagai konfigurasi tetap. Hasil evaluasi menunjukkan Random Forest memperoleh MAE 9,3347 Watt, RMSE 16,2742 Watt, dan R-squared 0,9759, sedangkan XGBoost memperoleh MAE 9,4395 Watt, RMSE 15,2543 Watt, dan R-squared 0,9788. Pada subhimpunan data hasil pengukuran asli, XGBoost unggul pada seluruh metrik dengan MAE 13,4515 Watt, RMSE 19,3738 Watt, dan R-squared 0,9677, sehingga dinilai sebagai arsitektur model yang paling optimal. Analisis Feature importance menempatkan intensitas cahaya sebagai parameter paling dominan dengan kontribusi sekitar 98 persen, jauh melampaui suhu dan kelembapan.

Floating photovoltaic (PV) power plants exhibit microclimate characteristics that differ from ground-mounted installations due to the influence of the water surface, so estimating their power output requires an approach capable of handling non-linear relationships among weather parameters. This study aims to develop and compare the performance of the Random Forest and Extreme Gradient Boosting (XGBoost) algorithms in estimating the power output of a floating PV plant based on temperature, humidity, and light intensity, and to identify the most dominant parameter. Primary data were collected through an Internet of Things based acquisition system at the floating PV installation on the lake of Institut Teknologi PLN from 11 to 19 June 2026 using DHT22 and BH1750 sensors and a PZEM-017 DC module. From 6,293 rows of raw data, 3,123 rows of daytime data were obtained after cleaning, interpolation, and imputation based on light intensity similarity, with the power target computed from the product of voltage and current. All variables were normalized using the Min-Max method, while the model hyperparameters were set as a fixed configuration. The evaluation results show that Random Forest achieved an MAE of 9.3347 Watts, an RMSE of 16.2742 Watts, and an R-squared of 0.9759, whereas XGBoost achieved an MAE of 9.4395 Watts, an RMSE of 15.2543 Watts, and an R-squared of 0.9788. On the subset of original measured data, XGBoost outperformed on all metrics with an MAE of 13.4515 Watts, an RMSE of 19.3738 Watts, and an R-squared of 0.9677, and is therefore considered the most optimal model architecture. Feature importance analysis identified light intensity as the most dominant parameter, contributing approximately 98 percent, far exceeding temperature and humidity.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: PLTS Apung, XGBoost, Random Forest, estimasi daya, Feature importance, parameter iklim mikro. Floating PV, XGBoost, Random Forest, power estimation, Feature importance, microclimate parameters.
Subjects: Bidang Keilmuan > Algoritma
Bidang Keilmuan > Classification
Bidang Keilmuan > Data Analytics
Bidang Keilmuan > Data Clustering
Bidang Keilmuan > Data Science
Bidang Keilmuan > Energi Terbarukan
Bidang Keilmuan > Machine Learning
Bidang Keilmuan > Photovoltaic
Bidang Keilmuan > Power Plant
Bidang Keilmuan > Renewable Energy
Skripsi
Bidang Keilmuan > Solar Power Plant
Bidang Keilmuan > Teknik Informatika
Divisions: Fakultas Telematika Energi > S1 Teknik Informatika
Depositing User: FAKULTAS TELEMATIKA ENERGI
Date Deposited: 19 Aug 2026 07:24
Last Modified: 21 Sep 2026 07:17
URI: https://repository.itpln.ac.id/id/eprint/6971

Actions (login required)

View Item
View Item