OPTIMASI PENEMPATAN REMOTE SWITCHING DEVICE MENGGUNAKAN METODE HYBRID AHP – PSO UNTUK PENINGKATAN KEANDALAN JARINGAN DISTRIBUSI TEGANGAN MENENGAH 20kV

Rafi, Muhammad and Luqman, Luqman (2026) OPTIMASI PENEMPATAN REMOTE SWITCHING DEVICE MENGGUNAKAN METODE HYBRID AHP – PSO UNTUK PENINGKATAN KEANDALAN JARINGAN DISTRIBUSI TEGANGAN MENENGAH 20kV. Diploma thesis, Institut Teknologi PLN.

[thumbnail of Cover_Skripsi_202231036_Muhammad Rafi.pdf] Text
Cover_Skripsi_202231036_Muhammad Rafi.pdf

Download (152kB)
[thumbnail of Lembar Pengesahan_Skripsi_202231036_Muhammad Rafi.pdf] Text
Lembar Pengesahan_Skripsi_202231036_Muhammad Rafi.pdf

Download (227kB)
[thumbnail of Abstrak_Skripsi_202231036_Muhammad Rafi.pdf] Text
Abstrak_Skripsi_202231036_Muhammad Rafi.pdf

Download (213kB)
[thumbnail of BAB I_Skripsi_202231036_Muhammad Rafi.pdf] Text
BAB I_Skripsi_202231036_Muhammad Rafi.pdf

Download (211kB)
[thumbnail of BAB II_Skripsi_202231036_Muhammad Rafi.pdf] Text
BAB II_Skripsi_202231036_Muhammad Rafi.pdf

Download (568kB)
[thumbnail of BAB III_Skripsi_202231036_Muhammad Rafi.pdf] Text
BAB III_Skripsi_202231036_Muhammad Rafi.pdf
Restricted to Registered users only

Download (442kB)
[thumbnail of BAB IV_Skripsi_202231036_Muhammad Rafi.pdf] Text
BAB IV_Skripsi_202231036_Muhammad Rafi.pdf
Restricted to Registered users only

Download (396kB)
[thumbnail of BAB V_Skripsi_202231036_Muhammad Rafi.pdf] Text
BAB V_Skripsi_202231036_Muhammad Rafi.pdf
Restricted to Registered users only

Download (195kB)
[thumbnail of Daftar Pustaka_Skripsi_202231036_Muhammad Rafi.pdf] Text
Daftar Pustaka_Skripsi_202231036_Muhammad Rafi.pdf

Download (196kB)
[thumbnail of Skripsi_202231036_Muhammad Rafi.pdf] Text
Skripsi_202231036_Muhammad Rafi.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Keandalan jaringan distribusi tenaga listrik tegangan menengah 20kV merupakan aspek penting dalam menjaga keberlangsungan dan mutu pelayanan kelistrikan kepada
pelanggan. Evaluasi kinerja jaringan distribusi umumnya dilakukan menggunakan indikator keandalan, antara lain System Average Interruption Duration Index (SAIDI),
dan System Average Interruption Frequency Index (SAIFI). Salah satu strategi yang efektif untuk meningkatkan keandalan jaringan adalah pemanfaatan Remote Switching Device (RSD) seperti recloser dan sectionalizer. Namun, manfaat perangkat
tersebut sangat dipengaruhi oleh ketepatan penentuan lokasi pemasangannya. Penelitian ini mengembangkan suatu model optimasi penempatan RSD dengan mengombinasikan metode Analytic Hierarchy Process (AHP) dan Particle Swarm
Optimization (PSO). AHP digunakan untuk menetapkan bobot kepentingan relatif dari setiap kriteria teknis yang berpengaruh terhadap keandalan jaringan, sedangkan PSO
diterapkan untuk memperoleh konfigurasi lokasi RSD yang paling optimal berdasarkan fungsi objektif keandalan. Model yang diusulkan diuji pada jaringan distribusi aktual yang terdiri atas 149 feeder di PT PLN (Persero) UID UP3 Serpong
dengan memanfaatkan data gangguan historis, struktur topologi jaringan, jumlah pelanggan, kapasitas beban, serta jarak antar gardu. Hasil penelitian menunjukkan bahwa pendekatan AHP–PSO mampu menghasilkan penurunan nilai SAIDI dan SAIFI, secara signifikan dibandingkan kondisi awal, sekaligus menyediakan kerangka pengambilan keputusan yang lebih objektif dan efisien dalam perencanaan otomasi
jaringan distribusi.
The reliability of 20kV medium-voltage power distribution networks is a key factor in maintaining the continuity and quality of electricity supply. Distribution system
performance is commonly assessed using reliability indices such as the System Average Interruption Duration Index (SAIDI) and System Average Interruption Frequency Index (SAIFI). The application of Remote Switching Devices (RSD),
including reclosers and sectionalizers, represents an effective measure to enhance network reliability; however, the overall effectiveness of these devices is highly
dependent on the accuracy of their placement locations. This study presents an optimization framework for RSD placement by integrating the Analytic Hierarchy Process (AHP) and Particle Swarm Optimization (PSO). AHP is employed to
determine the relative importance weights of technical criteria influencing distribution system reliability, while PSO is utilized to identify the most optimal RSD placement
configuration based on a reliability-oriented objective function. The proposed framework is applied to a real-world distribution network consisting of 149 feeders operated by PT PLN (Persero) UP3 Serpong, using historical outage records, network topology data, customer information, load capacity, and inter-substation distances.
The findings indicate that the proposed AHP–PSO approach effectively reduces SAIDI and SAIFI values compared to the existing network condition, while providing a more objective and efficient decision-support framework for distribution network automation planning.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: keandalan jaringan distribusi, Remote Switching Device, SAIDI, SAIFI, Analytic Hierarchy Process, Particle Swarm Optimization.
Subjects: Bidang Keilmuan > Algoritma
Bidang Keilmuan > Distribusi Tenaga Listrik
Bidang Keilmuan > Machine Learning
Bidang Keilmuan > Power System Network
Bidang Keilmuan > Power Systems
Bidang Keilmuan > SCADA
Skripsi
Bidang Keilmuan > System Performance
Bidang Keilmuan > Teknik Informatika
Divisions: Fakultas Telematika Energi > S1 Teknik Informatika
Depositing User: FAKULTAS TELEMATIKA ENERGI
Date Deposited: 18 Aug 2026 06:51
Last Modified: 18 Sep 2026 03:55
URI: https://repository.itpln.ac.id/id/eprint/6984

Actions (login required)

View Item
View Item