Izzami, M. Naufal and Sari, Dewi Purnama (2025) IMPLEMENTASI PARALLEL UPS UNTUK KONTINUITAS PENYALURAN DAYA LISTRIK PADA DATA CENTER BIZNET. Diploma thesis, Institut Teknologi PLN.
![[thumbnail of SKRIPSI 202011372 M NAUFAL IZZAMI.pdf]](https://repository.itpln.ac.id/style/images/fileicons/text.png)
SKRIPSI 202011372 M NAUFAL IZZAMI.pdf
Restricted to Repository staff only
Download (5MB)
Abstract
Penelitian ini membahas penerapan sistem Uninterruptible Power Supply (UPS) parallel untuk memastikan kontinuitas pasokan daya listrik di Data Center Biznet. Sebagai infrastruktur penting, data center memerlukan suplai listrik yang stabil untuk mencegah kerusakan pada perangkat server akibat gangguan kelistrikan, seperti lonjakan tegangan, pemadaman mendadak, atau ketidakstabilan daya. Hasil analisis menunjukkan bahwa kapasitas daya UPS yang digunakan saat ini mengalami kelebihan beban sebesar 102,5% dari kapasitas 160 KVA, sehingga tidak mampu menjaga kontinuitas penyaluran daya secara optimal. Dengan implementasi dua UPS paralel masing-masing 200 KVA, beban turun menjadi 41%, menunjukkan bahwa sistem dapat beroperasi dengan lebih aman, efisien, dan memiliki redundansi yang lebih baik. Selain meningkatkan kapasitas daya, UPS paralel juga berfungsi sebagai stabilizer tegangan yang dapat menjaga kualitas suplai listrik agar tetap dalam batas aman. Implementasi sistem ini sangat penting untuk memastikan keandalan operasional data center, mencegah gangguan yang dapat menyebabkan downtime, serta melindungi peralatan kritis dari potensi kerusakan akibat ketidakstabilan daya. Oleh karena itu, penggunaan UPS paralel merupakan solusi yang efektif dalam meningkatkan efisiensi dan kestabilan sistem kelistrikan di data center.
This study discusses the implementation of a parallel Uninterruptible Power Supply (UPS) system to ensure the continuity of power supply at Biznet Data Center. As a critical infrastructure, data centers require a stable power supply to prevent damage to server equipment due to electrical disturbances such as voltage surges, sudden power outages, or power instability. The analysis results indicate that the current UPS capacity is overloaded by 102.5% of its 160 KVA capacity, making it unable to maintain continuous power distribution optimally. With the implementation of two parallel UPS units of 200 KVA each, the load decreases to 41%, demonstrating that the system can operate more safely, efficiently, and with better redundancy. In addition to increasing power capacity, the parallel UPS also functions as a voltage stabilizer, ensuring that the power supply quality remains within safe limits. Implementing this system is crucial to ensuring the reliability of data center operations, preventing disruptions that could cause downtime, and protecting critical equipment from potential damage due to power instability. Therefore, using a parallel UPS is an effective solution for improving the efficiency and stability of the power system in a data center.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | UPS paralel, data center, kontinuitas daya, keandalan listrik. Parallel UPS, data center, power continuity, power reliability. |
Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
Depositing User: | Budi Herdiansyah |
Date Deposited: | 25 Aug 2025 07:29 |
Last Modified: | 29 Aug 2025 06:59 |
URI: | https://repository.itpln.ac.id/id/eprint/100 |