STUDI KINERJA DAN KEANDALAN RELAY DISTANCE PADA PENGHANTAR BAY LINE GI 150 KV PETUKANGAN

Blancira, Novriando and Samsurizal, Samsurizal (2025) STUDI KINERJA DAN KEANDALAN RELAY DISTANCE PADA PENGHANTAR BAY LINE GI 150 KV PETUKANGAN. Diploma thesis, Institut Teknologi PLN.

[thumbnail of SKRIPSI 202211588 NOVRIANDO BLANCIRA.pdf] Text
SKRIPSI 202211588 NOVRIANDO BLANCIRA.pdf
Restricted to Repository staff only

Download (2MB)

Abstract

Relai merupakan salah satu peralatan proteksi yang sangat vital. Kinerja relai menjadi hal yang sangat penting bagi setiap gardu induk. Relai jarak (distance relay) adalah salah satu proteksi utama pada sistem proteksi jaringan transmisi saluran udara tegangan tinggi (SUTT) 150 KV. Sistem kerja relai distance adalah menggunakan pengukuran tegangan dan arus agar mendapatkan impedansi gangguan pada saluran transmisi kemudian membandingkannya dengan impedansi setting relai distance. Jika nilai impedansi gangguan lebih kecil dari impedansi setting relai distance maka relai akan trip. Penelitian ini dilakukan untuk mengkaji ulang kinerja dan keandalan relay distance yang kondisinya sudah lama pada GI 150 kV Petukangan. Pada tugas akhir ini penulis menggunakan metode kuantitatif untuk mendapatkan hasil perhitungan impedansi zona dan impedansi gangguan, Dari penelitian yang dilakukan oleh penulis, didapat impedansi per zona yaitu zona 1 sebesar 0,2432+�1,6646 Ω, zona 2 sebesar 0,4194+j2,8704Ω, dan zona 3 sebesar 0,6952+j4,7577Ω. Untuk zona impedansi gangguan didapati adalah sebagai berikut, gangguan 1 fasa ke tanah sebesar 0,239+j1,66 Ω, gangguan 2 fasa sebesar 0,24+j1,66 Ω, dan gangguan 3 fasa sebesar 0,238+j1,64 Ω

Relay is one of the most vital protection equipment. Relay performance is very important for every substation. Distance relay is one of the main protections in the 150 KV high voltage overhead transmission line (SUTT) network protection system. The distance relay working system is to use voltage and current measurements to obtain the disturbance impedance on the transmission line and then compare it with the distance relay setting impedance. If the disturbance impedance value is smaller than the distance relay setting impedance, the relay will trip. This study was conducted to review the performance and reliability of the distance relay whose condition has been old at the 150 kV Petukangan GI. In this final project, the author uses a quantitative method to obtain the calculation results of zone impedance and disturbance impedance. From the research conducted by the author, the impedance per zone is obtained, namely zone 1 0,2432+�1,6646 Ω, zone 2 is 0.4194 + j2.8704Ω, and zone 3 is 0.6952 + j4.7577Ω. For the disturbance impedance zone, the following are obtained, 1-phase to ground disturbance is 0,238+j1,64 Ω, 2- phase disturbance is 0,24+j1,66 Ω, and 3-phase disturbance is 0,238+j1,64 Ω.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Relai Jarak, Impedansi, Zona Pengaman A protection relay, Impedance, Protection zones
Subjects: Bidang Keilmuan > Electro Engineering
Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro