ANALISIS PENGARUH MODIFIKASI LINE COOLER TERHADAP STG PLTMGU LOMBOK PEAKER

Wibisono, Anton and SUDIRMANTO, SUDIRMANTO (2024) ANALISIS PENGARUH MODIFIKASI LINE COOLER TERHADAP STG PLTMGU LOMBOK PEAKER. Diploma thesis, ITPLN.

[thumbnail of 202112078 Anton Wibisono (2).pdf] Text
202112078 Anton Wibisono (2).pdf
Restricted to Repository staff only

Download (7MB)

Abstract

Penelitian ini bertujuan untuk: (1) Mengetahui pengaruh modifikasi line intake water pond terhadap daya mampu STG PLTMGU. (2) Menghitung jumlah gangguan STG PLTMGU yang diakibatkan level intake water pond. (3) Menghitung manfaat finansial dari modifikasi Line Cooler. STG atau kepanjangan dari Steam Turbine Generation memiliki daya terpasang 11,6 MW dengan daya mampu 10,4 MW. STG merupakan hasil combined cycle gas buang engine PLTMGU yang diproses melalui HRSG untuk memutar generator steamnya. Terdapat 2 unit CWP (Condensor Water Pump) untuk kebutuhan pendingin STG. Surut air laut yang rutin terjadi dengan intensitas rata-rata 87
jam/bulan menyebabkan STG mengalami derating, atau bahkan tidak dapat beroperasi sama sekali karena level air pada intake water pond pada level trip yaitu 3,5 meter. Oleh karena adanya masalah pasang surut air laut yang terjadi
dan untuk menjaga level air pada intake water pond diatas 3,5 meter, maka dilakukan modifikasi Line Cooler STG PLTMGU Lombok Peaker untuk menjaga performa STG sehingga mampu menambah pasokan daya listrik ke sistem kelistrikan Pulau Lombok.
This research aims to: (1) Know the influence of the modification of the water intake line pond on the capacity of the PLTMGU STG. (2) Calculate the number of STG interference that is caused by the level of water intakes pond. (3) Calculates the financial benefits of the modification of the Line Cooler. STG, or Steam Turbine Generation, has an installed power of 11.6 MW with a capacity of 10.4 MW. STG is the result of the combined cycle gas exhaust engine PLTMGU that is processed through HRSG to rotate the steam generator. There are 2 units of CWP (Condensor Water Pump) for STG cooling needs. A regular
rush of sea water occurring at an average intensity of 87 hours/month caused STG to suffer derating, or even not to operate at all because of the water level on the water intake pond at the trip level is 3.5 meters. Because of the problem with the installation of the rushing that occurred and to keep the level of water on the intake water pond above 3,5 meters, then made a modification of the
Cooler Line STG PLTMGU Lombok Peaker to maintain the performance of STG so that it can add the power supply to the electricity system of Lombok Island.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: STG, HRSG, Line Cooler, intake water pond STG, HRSG, Line Cooler, intake water pond
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin
Depositing User: Nurul Hidayati
Date Deposited: 27 Aug 2025 03:43
Last Modified: 27 Aug 2025 03:43
URI: https://repository.itpln.ac.id/id/eprint/212