Prayoga, Bagus and Hendri, Hendri (2024) ANALISIS EFEKTIVITAS AIR PREHEATER A TIPE LJUNGSTROM SEBELUM DAN SESUDAH OVERHAUL UNIT 2 PT. PLN INDONESIA POWER PLTU JABAR 2 PELABUHAN RATU 3X350 MW. Diploma thesis, ITPLN.
![[thumbnail of 202012103-Skripsi Bagus Prayoga.pdf]](https://repository.itpln.ac.id/style/images/fileicons/text.png)
202012103-Skripsi Bagus Prayoga.pdf
Restricted to Repository staff only
Download (7MB)
Abstract
Air preheater adalah pemanas awal udara sebelum masuk ke ruang pembakaran dengan memanfaatkan gas buang hasil pembakaran sebagai pemanas awalnya. Air preheater
yang digunakan pada PLTU Jabar 2 Pelabuhan Ratu 3x350 MW adalah jenis Ljungstrom tri sector. Data dari sebelum dan sesudah overhaul inisehingga perlu dikaji pengaruh
penggantian elemen cold element terhadap nilai efektivitas dengan variasi beban yaitu 215 (50%), 270 (75%), dan 330 (100%). Dari analisa sebelum penggantian elemen pada
sisi cold element dengan beban 215 (50%) didapat nilai efektivitas sebesar 0,892, beban 270 (75%) didapat nilai efektivitas sebesar 0,878, dan beban 330 (100%) didapat nilai efektivitas sebesar 0,886. Dan setelah penggantian elemen pada sisi cold element dengan beban 215 (50%) didapat nilai efektivitas sebesar 0,917, beban 270 (75%) didapat nilai efektivitas sebesar 0,916, dan beban 330 (100%) didapat nilai efektivitas sebesar 0,905. Dalam hal kebocoran (air leakage) telah terjadi penurunan pada setiap beban setelah dilakukan penggantian elemen pada sisi cold element dan penyesuaian pada celah seal. Semakin tinggi efektivitasnya maka semakin baik kinerja air preheater dalam
meningkatkan efisiensi boiler.
Air preheater is a preheater for air before it enters the combustion chamber by utilizing exhaust gas from combustion as the initial heater. The air preheater used in PLTU Jabar
2 Pelabuhan Ratu 3x350 MW is the Ljungstrom tri sector type. Data from before and after the overhaul means it is necessary to study the effect of cold element replacement on the effectiveness value with load variations, namely 215 (50%), 270 (75%), and 330 (100%). From the analysis before replacing elements on the cold side of the element with a load of 215(50%) an effectiveness value was obtained of 0.892, a load of 270(75%) obtained an effectiveness value of 0.878, and a load of 330(100%) obtained an effectiveness value of 0.886. And after replacing the element on the cold side of the element with a load of 215(50%) the effectiveness value is 0.917, the load 270(75%) gets an effectiveness value of 0.916, and the load 330(100%) gets an effectiveness value of 0.905. In the case of air leakage, there has been a decrease in each load after replacing the elements on the cold side of the elements and adjusting the seal gap. The higher the effectiveness, the better the performance of the air preheater in increasing boiler efficiency.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Air Preheater Ljungtrom, Efektivitas, Penggantian Cold Element Air Preheater Ljungstrom, Effectiveness, Replacement of Cold Elements |
Subjects: | Skripsi Bidang Keilmuan > Teknik Mesin |
Divisions: | Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin |
Depositing User: | Nurul Hidayati |
Date Deposited: | 27 Aug 2025 03:52 |