Rusmansyah, Denny and Hajar, Ibnu and Pasra, Nurmiati (2021) ANALISIS VOLTAGE DROP PADA JARINGAN TEGANGAN RENDAH DENGAN METODE PECAH BEBAN PADA GARDU KH 007 DI PT PLN (Persero) UP3 PAMEKASAN. Diploma thesis, ITPLN.
SKRIPSI 201611166 DENNY RUSMANSYAH.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Pada sistem pengoperasian tenaga listrik, kita memerlukan adanya kualitas pelayanan yang baik. Salah satu contohnya yaitu memberikan nilai tegangan yang baik kepada pelanggan dan tidak adanya gangguan voltage drop. Berdasarkan SPLN No 1 : 1978, tegangan pelayanan maksimum 5% dan minimumnya 10% dari tegangan nominal ideal jaringan tegangan rendah yaitu 220 Volt. Salah satu lokasi yang mengalami gangguan voltage drop adalah Desa Pakandangan Tengah, Sumenep. Berdasarkan hasil analisa yang telah dilakukan oleh petugas divisi jaringan PT PLN UP3 Pamekasan, ternyata voltage drop yang terjadi di Desa Pakandangan Tengah diakibatkan oleh jauhnya lokasi tersebut dari gardu KH 007 yang mensuplai listriknya, jaraknya yaitu 643 meter. Kemudian, daerah disekitaran lokasi tersebut juga memiliki beban beban yang tinggi dikarenakan banyaknya berdiri pemukiman warga. Oleh karena itu, perlu dilakukannya perbaikan di daerah tersebut dengan menggunakan metode pecah beban. Metode ini dilakukan dengan cara memindahkan beban dijaringan yang lama ke jaringan yang baru, dimana jaringan yang dipindah yaitu 5 tiang terakhir pada jurusan ini, sehingga beban yang di topang oleh satu jurusan tersebut tidak mengalami voltage drop. Hasil yang didapat setelah melakukan pecah beban yaitu tegangan pada sisi terima naik menjadi di fasa R 200 Volt, fasa S 212 Volt, dan fasa T 202 Volt. Dimana sebelumnya nilai dari tegangan pada sisi terimanya yaitu fasa R 189 Volt, fasa S 206 Volt, dan fasa T 194 Volt.
In the operation of the electric power system, good quality service is needed. One of them is the voltage value received by the customer does not get a voltage drop. Based on SPLN No.1: 1978, the service voltage is a maximum of 5% and a minimum of 10% of the nominal voltage of the Low Voltage Network that is 220 Volt. One of the locations experiencing voltage drop problems is on the Central Pakandangan Village, Sumenep. Based on an analysis do by the PT PLN UP3 Pamekasan Network division, it turns out that the voltage drop that occurred on Central Pakandangan Village caused by the location. The location is to far from the KH 007 distribution substation, which is 643 meters. Then, the area around the location also has a high burden due to the many standing residential settlements. Therefore, it is necessary to break the load on the network. This method is done by moving or transferring part of the load from the old network to the new network. Which is the last 5 poles in this line. so the load supported by one line does not have voltage drop. The result obtained after performing the load break is that the voltage on the receiving side rises to phase R 200 Volt, phase S 212 Volt, and phase T 202 Volt. Where previously the value of the voltage on the receiving side is phase R 189 Volt, phase S 206 Volt, and phase T 194 Volt.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Voltage Drop, Pecah Beban, Tegangan Rendah Voltage Drop, Current Load Break Method, Low Voltage |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 15 Oct 2025 04:40 |
| Last Modified: | 15 Oct 2025 04:40 |
| URI: | https://repository.itpln.ac.id/id/eprint/2348 |