Rahman, Amansyah Saputra and Diantari, Retno Aita and aziz, Hastuti (2021) STUDI SETTING RECLOSER SEBAGAI PROTEKSI ARUS GANGGUAN HUBUNG SINGKAT PADA PENYULANG KAZE DI PT. PLN (PERSERO) UP3 CENGKARENG. Diploma thesis, ITPLN.
SKRIPSI 201611281 AMANSYAH SAPUTRA RAHMAN.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Dalam memenuhi kebutuhan tenaga listrik, terjadi gangguan arus pada sistem jaringan SUTM di PT.PLN (Persero) UP3 Cengkareng sehingga menghambatnya saluran pasokan tenaga listrik berupa arus gangguan. Akibat gangguan arus tersebut perlu dilakukan penanganan dengan cara pemasangan Recloser sebagai proteksi arus gangguan. Recloser adalah suatu peralatan pemutus aliran listrik secara otomatis. Peralatan ini dapat bekerja ketika ada arus gangguan maka akan memerintahkan operasi membuka dan menutup kepada pemutus aliran listrik secara otomatis sesuai waktu yang telah diatur. Penelitian ini bertujuan untuk menganalisis pemasangan Recloser sebagai proteksi arus gangguan hubung singkat pada penyulang Kaze di PT. PLN (Persero) UP3 Cengkareng. Metode yang dilakukan pada penelitian adalah menghitung arus gangguan hubung singkat dan setting Reclosernya. Hasil perhitungan menunjukkan bahwa gangguan tiga fasa pada titik 0 kilometer merupakan arus gangguan maksimum yaitu 12396 ∠ -90° A, sedangkan gangguan tiga fasa pada titik 7 kilometer merupakan arus gangguan minimum yaitu 3224 ∠ -65° A. Pada penyulang kaze, penempatan Recloser terletak pada titik 5,2 km. Arus gangguan hubung singkat 3 fasa yang terletak pada titik 5,2 kilometer yaitu sebesar 4014 Ampere. Nilai setting Recloser 0,44 ampere dengan setting TMS (Time Multiplier Setting) Standart Inverse dan di dapat waktu Recloser bekerja setelah selang waktu 0,30 detik.
In meeting the needs of electricity, there is a disruption of current in the SUTM network system at PT. PLN (Persero) UP3 Cengkareng thus inhibiting the power supply line in the form of disruption currents. As a result of the current disruption it is necessary to handle the installation of Recloser as interference current protection. Recloser is an automatic electrical circuit breaker. This equipment can work when there is a interference current it will order the operation to open and close to the power circuit breaker automatically according to the time set. This study aims to analyze the installation of Recloser as a protection for short circuit fault currents in Kaze feeders at PT. PLN (Persero) UP3 Cengkareng. The method used in this research is to calculate the short circuit fault current and its Recloser setting. The calculation results show that the three phase disturbances at kilometer 0 are the maximum interference current of 12396 ∠ -90 ° A, while the disruption of three phases at kilometer 7 is a minimum interference current of 3224 ∠ -65 ° A. In kaze feeder, Recloser hatching is located at km 5.2. Short circuit interference current 3 phase located at kilometer 5.2 which is 4014 Ampere. Recloser setting value of 0.44 ampere with TMS setting (Time Multiplier Setting) Standart Inverse and in can Recloser time work after an interval of 0.30 seconds.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Recloser, Time Multiplier Setting, Gangguan Hubung Singkat Recloser, Time Multiplier Setting, Short Circuit |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Informatika |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |