ANALISA KEANDALAN JARINGAN ZERO DOWN TIME PADA KAWASAN SCBD (SUDIRMAN CENTRAL BUSINESS DISTRICT)

MELIDA, NISRA and Hasanah, Aas Wasri and Husada, Hendrianto (2021) ANALISA KEANDALAN JARINGAN ZERO DOWN TIME PADA KAWASAN SCBD (SUDIRMAN CENTRAL BUSINESS DISTRICT). Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 201611035 NISRA MELIDA.pdf] Text
SKRIPSI 201611035 NISRA MELIDA.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Keandalan pasokan listrik merupakan hal yang terpenting dalam mendukung proses perekonomian, dan jumlah permintaan juga akan meningkat seiring bertambahnya jumlah pelanggan setiap tahunnya. Dikarenakan bertambahnya jumlah pelanggan maka keandalan pada penyaluran listrik juga harus semakin baik, salah satu faktor yang mempengaruhi keandalan pada penyaluran listrik adalah konfigurasi jaringannya. Jaringan ZDT merupakan program yang dilakukan oleh pihak PLN dalam meningkatkan keandalan jaringan tanpa terjadi pemadaman pada kawasan SCBD (Sudirman Central Business District), jaringan Zero Down Time dapat dipasang apabila telah memenuhi beberapa syarat yaitu seperti 2 buah penyulang yang dipasang paralel, suplai daya berasal dari trafo yang dipasang pada gardu induk utama atau gardu hubung, kubikel yang dipakai adalah CBO karena dilengkapi dengan relay differential, dan harus memiliki ketersediaan komunikasi agar relay dapat bekerja dengan baik. Indeks keandalan yang dibahas pada penelitian ini adalah nilai dari SAIDI dan SAIFI, dimana untuk nilai keandalan tanpa terjadi gangguan blackout adalah sebesar SAIDI 0,016974 jam/pelanggan/tahun dan SAIFI 0,028311 pemadaman/pelanggan/tahun dan untuk nilai keandalan keseluruhan dengan adanya gangguan blackout yaitu SAIDI yang di peroleh sebesar 46,06014 jam/pelanggan/tahun dan nilai SAIFInya sebesar 4,56607 pemadaman/pelanggan/tahun. Hasil dari perhitungan tersebut melibihi standar yang telah ditetapkan oleh SPLN 59:1985 yaitu SAIDI sebesar ≤ 12,842 jam/pelanggan/tahun dan SAIFI sebesar ≤ 2,541 pemadaman/pelanggan/tahun hal ini dikarenakan terjadi gangguan blackout pada transmisi 150 kV.

The reliability of electricity supply is the most important thing in supporting the economic process, and the amount of demand will also increase as the number of customers increases each year. Due to the increase in the number of subscribers, the reliability of electricity distribution must also be better, one of the factors that affect the reliability of electricity distribution is the network configuration. The ZDT network is a program carried out by PLN in improving network reliability without blackouts in the SCBD (Sudirman Central Business District) area, the Zero Down Time network can be installed if it meets several conditions, such as 2 feeders installed parallel, power supply comes from The transformer that is installed in the main substation or switch station, the cubicle used is CBO because it is equipped with a differential relay, and must have the availability of communication so that the relay can work properly. The index discussed in this study is the value of SAIDI and SAIFI, where the value of the outage disturbance problem is SAIDI 0.016974 hours/customer/year and SAIFI 0.028311 blackout / customer / year and to assess the overall presence of outage disturbances, namely SAIDI which is obtained for 46,06014 hours / customer / year and the SAIFI value of 4.56607 blackouts / subscribers/year. The results of these calculations exceed the standards set by SPLN 59: 1985, namely SAIDI of ≤ 12,842 hours / customer / year and SAIFI of ≤ 2,541 blackouts / subscriber / year this occurs due to outages on 150 kV transmission.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Keandalan, ZDT, SAIDI ,SAIFI Reliability, ZDT, SAIDI, SAIFI
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 15 Oct 2025 08:20
Last Modified: 15 Oct 2025 08:20
URI: https://repository.itpln.ac.id/id/eprint/2386

Actions (login required)

View Item
View Item