Ramadhan, Raxha Vijaya and Pawenary, Pawenary and Gusti Pahiyanti, Novi (2021) STUDI ANALISIS DAMPAK HARMONISA TERHADAP AKURASI ENERGI METER PADA PELANGGAN BISNIS DAN DESAIN FILTER PASIF SINGLE TUNED. Diploma thesis, ITPLN.
SKRIPSI 201611086 RAXHA VIJAYA RAMADHAN.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Salah satu indikator untuk melihat kualitas daya atau power quality pada sistem tenaga listrik adalah dengan melihat tingkat harmonisa sistem, yang mana tingkat harmonisa tersebut dipengaruhi oleh beban dengan komponen-komponen elektronika seperti beban induktif dan kapasitif. Tujuan dari penelitian adalah untuk melakukan analisis besar harmonisa arus dan tegangan pada pelanggan tenaga listrik, kemudian melihat pengaruhnya terhadap akurasi pembacaan kWh meter pelanggan tersebut serta mendesain filter pasif single tuned filter pada PT. Pura Mayungan. Metode yang digunakan dalam penelitian ini adalah metode kuantitatif dengan menghitung akurasi pembacaan energi kWh meter, dan perhitungan untuk desain filter pasif. Hasil dari penelitian dengan pengambilan data selama 7 hari menunjukkan bahwa harmonisa tegangan terbesar yaitu 1,41%, dan yang terkecil adalah 1,23%, untuk harmonisa arus terbesar yaitu 42,2% dan terkecil yaitu 14,15%. Tingkat akurasi eror pada energi meter yaitu 57,94% sampai dengan -31,47%, sehingga untuk desain filter pasif yang didesain mampu menurunkan THD tegangan orde ke-5 dari 1,41% menjadi 0,06%.
One of the indicators to see the quality of power in the electric power system is to look at the level of harmonic of the system, where the level of harmonic is influenced by the load with electronic components such as inductive and capacitive loads. The purpose of the study was to perform a large analysis of current and voltage harmonics on electric power customers, then look at its effect on the accuracy of the customer's kWh meter readings as well as design a single tuned passive filter filter PT. Pura Mayungan. The method used in this study is quantitative method by calculating the accuracy of kWh meter energy reading, and calculation for passive filter design. The results of the study with data collection for 7 days showed that the largest voltage harmonia is 1.41 %, and the smallest is 1.23 %, for the largest current harmonia is 42.2 % and the smallest is 14.15 %. Error accuracy rate in energy meters is 57.94 % to -31.47 %, so that for passive filter design designed to reduce harmonia of the 5th order from 1,41 % to 0,06 %.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Filter Pasif, Harmonisa, kWh Meter, Single Tuned Passive Filter, Harmonisa, kWh Meter, Single Tuned |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 15 Oct 2025 08:50 |
| Last Modified: | 15 Oct 2025 08:50 |
| URI: | https://repository.itpln.ac.id/id/eprint/2393 |