Kubikel distribusi 20kV merupakan sekumpulan peralatan listrik yang dipasang di gardu induk penghubung distribusi yang berfungsi sebagai pemutus arus, pembagi tegangan, penyambung, pengontrol dan perangkat proteksi untuk sistem catu daya tegangan 20 kV. Salah satu hal yang dapat menyebabkan turunnya keandalan sebuah kubikel yaitu terjadinya gangguan, gangguan sendiri dapat disebabkan oleh berbagai faktor salah satunya faktor kelembaban. Kelembaban dapat menyebabkan terjadinya gangguan korona, korona merupakan fenomena yang terjadi saat udara sekitar penghantar atau konduktor terionisasi akibat naiknya kelembaban yang disebabkan penurunan suhu sehingga menyebabkan terjadinya pelepasan muatan yang mengakibatkan kegagalan isolasi. Pada penilitan yang dilakukan metode yang digunakan adalah metode kuantitatif dimana diperoleh data yang menunjukan bahwa pada kubikel riser (Interface Trafo 3) terindikasi gangguan korona yang menyebabkan kerugian baik finansial maupun material, hal itu dibuktikan secara visual, pengujian maupun perhitungan dimana kubikel riser (Interface Trafo 3) memiliki kelembaban relatif = 84%, tegangan pemunculan korona = 3,7319478962142 kV dan rugi-rugi daya = 4,0996426716698 kW. Akibat gangguan tersebut harus dilakukan penggantian pada terminasi kabel dan juga heater pada kubikel.

20kV distribution cubicle is a set of electrical equipment installed in distribution connecting substations that function as circuit breakers, voltage dividers, connectors, controllers and protection devices for the 20 kV voltage power supply system. One of the things that can cause a decrease in the reliability of a cubicle is the occurrence of interference, the disturbance itself can be caused by various factors, one of which is humidity. Humidity can cause corona interference, corona is a phenomenon that occurs when the air around a conductor or conductor is ionized due to increased humidity caused by a decrease in temperature, causing a discharge of charge resulting in insulation failure. In the research conducted, the method used is a quantitative method where data is obtained showing that the riser cubicle (Interface Transformer 3) indicates a corona disturbance that causes financial and material losses, this is proven visually, testing and calculations where the riser cubicle (Interface Transformer) 3) has a relative humidity = 84%, a corona voltage = 3,7319478962142 kV and a power loss = 4,0996426716698 kW. As a result of these disturbances, replacement of the cable termination and also the heater in the cubicle must be replaced.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Kubikel, Kelembaban, Korona Cubicle, Humidity, Corona
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 16 Oct 2025 08:19
Last Modified: 16 Oct 2025 08:19
URI: https://repository.itpln.ac.id/id/eprint/2452

Actions (login required)

View Item
View Item