OPTIMALISASI KEANDALAN SISTEM DISTRIBUSI 20 KV DI PT PLN (PERSERO) UP3 KENDARI DI PENYULANG TIELINE POMAALA

CABRINY, MOENICA and Azzahra, Septianissa (2022) OPTIMALISASI KEANDALAN SISTEM DISTRIBUSI 20 KV DI PT PLN (PERSERO) UP3 KENDARI DI PENYULANG TIELINE POMAALA. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202011338 MOENICA CABRINY.pdf] Text
SKRIPSI 202011338 MOENICA CABRINY.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Suatu sistem tenaga listrik memiliki tolak ukur untuk mengukur tingkat keandalan jaringan yang menyalurkan energi listrik ke beban secara kontinu yaitu indeks keandalan SAIDI & SAIFI. Oleh karena itu optimalisasi keandalan diperlukan untuk dapat mencari nilai terbaik dari suatu indeks keandalan yang didapat dari kegiatan evaluasi dan perbaikan tepat sasaran. Dari hasil Analisa melalui software Tableau, penyulang yang tidak memenuhi standar IEEE P1366-2003 adalah Penyulang Tieline Pomaala yaitu dengan pencapaian SAIDI 2,59 jam/plg/thn dan SAIFI 1,73 kali/plg/thn. Hasil evaluasi lebih lanjut, equipment Recloser/PMCB menjadi kontribusi terbesar kedua sehingga ditindak lanjuti dengan menghitung ulang koordinasi proteksi dan simulasi. Setelah dilakukan penyesuaian sempurna koordinasi proteksi, data menunjukkan penurunan SAIDI & SAIFI pada Penyulang Tieline Pomaala tahun 2022 equipment Recloser/PMCB menjadi nihil 0 menit/plg/tahun dan 0 kali/plg/tahun, dari sebelumnya di tahun 2021 menyumbang 22,2 menit/plg/tahun dan 0,191 kali/plg/tahun.

An electric power system has a benchmark to measure the level of reliability of the network that delivers electrical energy to the load continuously, namely the SAIDI & SAIFI reliability index. Therefore, optimization of reliability is needed to be able to find the best value of a reliability index obtained from evaluation and improvement activities on target. From the results of the analysis through the Tableau software, the feeder that did not meet the IEEE P1366-2003 standard was the Tieline Pomaala feeder with the achievement of SAIDI 2.59 hour/plg/year and SAIFI 1.73 times/plg/year. The result of further evaluation, equipment Recloser/PMCB became the second largest contribution so that it was followed up by recalculating the coordination of protection and simulation. After the perfect adjustment of protection coordination, the data shows a decrease in SAIDI & SAIFI on the Tieline Pomaala Feeder in 2022 Recloser/PMCB equipment to zero 0 minutes/plg/year and 0 times/plg/year, from the previous year 2021 contributed 22.2 minutes/ plg/year and 0.191 times/plg/year

Item Type: Thesis (Diploma)
Uncontrolled Keywords: SAIDI, SAIFI, Koordinasi Proteksi SAIDI, SAIFI, protection coordination
Subjects: Skripsi