Marsaoly, Nuku Wijaya and Kartiria, Kartiria (2025) ANALISA EFISIENSI GENERATOR UNIT 1 DAN 2 DI PT. PLN INDONESIA POWER UBP PLTU JAWA BARAT 2 PALABUHAN RATU. Diploma thesis, Institut Teknologi PLN.
![[thumbnail of SKRIPSI 202211596 NUKU WIJAYA MARSAOLY.pdf]](https://repository.itpln.ac.id/style/images/fileicons/text.png)
SKRIPSI 202211596 NUKU WIJAYA MARSAOLY.pdf
Restricted to Repository staff only
Download (6MB)
Abstract
PLTU Palabuhanratu 3x350 MW telah beroperasi selama 12 tahun semenjak COD tahun 2012, sehingga penelitian ini untuk mengetahui nilai efisiensi generator beserta rugi daya yang terdapat pada generator diantaranya rugi tembaga, rugi mekanik, rugi besi, dan rugi stray load yang menjadi faktor penting dalam menjaga kinerja dari pembangkit listrik. Dengan metode kuantitatif statistika didapat hasil perhitungan efisiensi selama 7 hari dalam 24 jam pada generator unit 2 dengan pembeban tertinggi pada tanggal 1/10/2024 dengan beban 300 MW rata-rata selama 24 jam serta rugi daya total yang didapat sebesar 2.826605 MW efisiensi generator 99.06%, sedangkan pada generator unit 1 didapat dengan rata-rata pembebanan tertinggi pada tanggal 1/10/2024 dengan beban 307 MW selama 24 jam serta didapat nilai rugi daya total sebesar 2.8137475 MW diperoleh efisiensi generator sebesar 99.09%, sedangkan pembeban terendah pada unit 2 terdapat pada tanggal 2/10/2024 diperoleh efisiensi sebesar 98.87% dengan nilai rugi daya total sebesar 2.456769 MW, dengan beban rata-rata 215 MW selama 24 jam, dan untuk unit 1 pada tanggal 6/10/2024 diperoleh efisiensi sebesar 99.00%, serta nilai rugi daya total didapat 2.543449 MW dengan rata-rata pembebanan 252 MW selama 24 jam beroperasi. Maka nilai efisiensi generator pada unit 2 dan unit 1 pada PLTU Palabuhanratu menunjukan bahwa generator efisiens dengan mengacu pada manual book shanghai electric co, ltd dengan nilai efisiensi generator sebesar 98.85%. Sehingga apabila semakin tinggi beban yang diberikan dan semakin tinggi nilai arus generator maka nilai efisiensi pada generator akan semakin tinggi.
The Palabuhanratu 3x350 MW PLTU has been operating for 12 years since COD in 2012, so this study is to determine the generator efficiency value along with the power losses in the generator including copper losses, mechanical losses, iron losses, and stray load losses which are important factors in maintaining the performance of the power plant. With the quantitative statistical method, the results of the efficiency calculation for 7 days in 24 hours on generator unit 2 with the highest load on 1/10/2024 with an average load of 300 MW for 24 hours and a total power loss of 2.826605 MW, the generator efficiency is 99.06%, while on generator unit 1, the highest average load was obtained on 1/10/2024 with a load of 307 MW for 24 hours and a total power loss value of 2.8137475 MW, the generator efficiency was 99.09%, while the lowest load on unit 2 was on 2/10/2024, an efficiency of 98.87% was obtained with a total power loss value of 2.456769 MW, with an average load of 215 MW for 24 hours, and for unit 1 on 6/10/2024, an efficiency of 99.00%, and the total power loss value is 2,543,449 MW with an average load of 252 MW for 24 hours of operation. So the generator efficiency value on unit 2 and unit 1 at the Palabuhanratu PLTU shows that the generator efficiency with reference to the Shanghai Electric Co., Ltd. manual book with a generator efficiency value of 98.85%. So if the higher the load given and the higher the generator current value, the efficiency value on the generator will be higher.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | PLTU Palabuhanratu, Efisiensi Generator, Rugi-Rugi Daya, Faktor Perubahan Nilai Efisiensi CFPP Palabuhanratu, Generator Efficiency, Power Losess, Factors Affecting Efficiency Changes |
Subjects: | Bidang Keilmuan > Electrical Engineering Skripsi Bidang Keilmuan > Teknik Elektro |
Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
Depositing User: | Budi Herdiansyah |
Date Deposited: | 27 Aug 2025 07:39 |
Last Modified: | 09 Sep 2025 01:44 |
URI: | https://repository.itpln.ac.id/id/eprint/250 |