Charisma, Vergusta Chandra and Pasra, Nurmiati (2022) ANALISIS UMUR INTERBUS TRANSFORMATOR (IBT) 275/150 kV 2X250 MVA TERHADAP PERUBAHAN PEMBEBANAN DAN SUHU LINGKUNGAN DI GARDU INDUK BENGKAYANG. Diploma thesis, ITPLN.
SKRIPSI 202011326 VERGUSTA CHANDRA CHARISMA.pdf
Restricted to Registered users only
Download (14MB)
Abstract
Gardu Induk Tegangan Ektra Tinggi Bengkayang memiliki 2 unit Interbus Transformer (IBT) 275/150 kV yang beroperasi secara komersial tahun 2016 untuk menginterkoneksi sitem kelistrikan Kalimantan Barat dengan Sarawak (Malaysia). Pada tahun 2021 sekitar 25% kebutuhan listrik Kalimantan Barat masih bergantung dengan suplai dari Malaysia sehingga susut umur transformator memerlukan perhatian lebih. Penelitian ini bertujuan untuk menganalisis pengaruh pembebanan dan suhu lingkungan terhadap susut umur trafo dengan menggunakan metode regresi linear. Berdasarkan metode tersebut diperoleh hubungan, bahwa semakin besar pembebanan dan semakin tinggi suhu lingkungan, maka semakin tinggi suhu hotspot. Suhu hotspot yang tinggi membuat laju susut umur trafo semakin besar sehingga umur pakai transformator semakin singkat. Berdasarkan data rata-rata pembebanan tahun 2021 didapat susut umur terburuk IBT unit 1 sebesar 0,0131 pada bulan Februari. Sementara susut umur IBT unit 2 sebesar 0,0067 pada bulan April. Perkiraan sisa umur IBT 1 adalah 20,52 tahun sementara IBT 2 adalah 20,53 tahun. Perhitungan besarnya beban optimum supaya susut umur IBT tidak melebihi 100% adalah 98,3% dari kapasitas terpasang atau 81,9 MVA dengan acuan suhu rata-rata tahun 2021 sebesar 32,09 oC.
The Bengkayang Extra High Voltage Substation has 2 Interbus Transformer (IBT) 275/150 kV which were commercially operated in 2016 to interconnect West Borneo electricity system with Sarawak (Malaysia). In 2021, around 25% of west borneo electricity system were supplied from Malaysia. Therefore, it needs more attention to the lifetime of the transformer. The purpose of this research was to analyze the effect of loading and ambient temperature on transformer lifetime by quantitative research methods and descriptive statistical analysis technique. Based on data analysis and calculation there are correlation that the greater the load and higher the ambient temperature, the higher is the hotpost temperature. Each increase in the hot spot temperature will increase the rate of loss-of-life of the transformer, which will result in shorter transformer lifetime. Based on the average loading data in 2021, the worst rate of loss-of-life for IBT unit 1 is 0,0131 in February with an estimated remaining life is 20,52 years. Meanwhile, the worst rate of loss-of-life for IBT unit 2 is 0,0067 in April with an estimated remaining life is 20,53 years. The optimum load so that rate of loss-of-life IBT doesn’t exceed 100% is 98,3% or 81,9 MVA with ambient temperature 32,09 0C
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | transformator, pembebanan, hotspot, susut umur transformer, loading, hotspot, loss of life |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 17 Oct 2025 08:21 |
| Last Modified: | 17 Oct 2025 08:21 |
| URI: | https://repository.itpln.ac.id/id/eprint/2529 |