ANALTSIS SUSUT UMUR TRANSFORMAT'OR DISTRIBUSI AKTBAT PEMBEBANAI\I LEBIII DI PT.PLN (PERSERO) UNIT LAYANAN PELANGGAN OESAO

Widanta, I Gede Agus and Pasra, Nurmiati (2022) ANALTSIS SUSUT UMUR TRANSFORMAT'OR DISTRIBUSI AKTBAT PEMBEBANAI\I LEBIII DI PT.PLN (PERSERO) UNIT LAYANAN PELANGGAN OESAO. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI 202011327 I GEDE AGUS WIDANTA.pdf] Text
SKRIPSI 202011327 I GEDE AGUS WIDANTA.pdf
Restricted to Registered users only

Download (6MB)

Abstract

Transformator adalah komponen penting dari sistem distribusi karena bertindak sebagai pengatur beban yang menggunakan prinsip induksi elektromagnetik dengan mengubah energi listrik dari satu rangkaian ke rangkaian lain melalui kopling magnetik. Faktor yang menyebabkan terjadinya susut umur transformator adalah pembebanan. Transformator Distribusi dengan kode gardu 43180KR047 dengan pembebanan puncak sebesar 28 % didapatkan susut umur per hari sebesar 6,72 jam, sehingga sisa umur transformator yang dimiliki selama 18,59 tahun. Transformator distribusi dengan kode gardu 43180KR065 dengan pembebanan puncak sebesar 33 % didapatkan susut umur per hari sebesar 7,24 jam, sehingga sisa umur transformator tersebut sebesar 18,24 tahun. Transformator distribusi dengan kode gardu 43180KR076 dengan pembebanan puncak sebesar 18,83 % didapatkan susut umur per hari sebesar 4,52 jam, sehingga sisa umur transformator tersebut sebesar 19,42 tahun. Semakin tinggi pembebanan pada sebuah transformator maka nilai dari susut umur juga akan semakin besar. Peningkatan temperatur sekitar akan mempengaruhi besarnya kenaikan temperatur hotspot, semakin tinggi nilai dari temperatur sekitar maka temperatur hotspot nya juga akan semakin besar begitupun dengan nilai dari susut umur transformator tersebut. Semakin tinggi pembebanan transformator maka nilai susut umur akan semakin besar dan sisa umur transformator semakin kecil.

The transformer is an important component of the distribution system because it acts as a load regulator using the principle of electromagnetic induction by converting electrical energy from one circuit to another through magnetic coupling. The factor that causes loss of life of the transformer is loading. Distribution Transformer with substation code 43180KR047 with a peak load of 28% obtained a daily life loss of 6.72 hours, so that the remaining life of the Transformer is 18.59 years. Distribution Transformer with substation code 43180KR065 with a peak loading of 33%, the age loss per day is 7.24 hours, so the remaining life of the transformer is 18,24 years. Distribution transformer with substation code 43180KR076 with a peak load of 18.83%, the age loss per day is 4.52 hours, so the remaining life of the transformer is 19,42 years. The higher the load on a transformer, the value of life shrinkage will also be greater. The increase in ambient temperature will affect the magnitude of the increase in the hot spot temperature, the higher the value of the ambient temperature, the hot spot temperature will also be greater as well as the value of the reduced life of the transformer. The higher the load on the transformer, the value of life shrinkage will be greater and the remaining life of the transformer will be smaller.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: transformator distribusi, susut umur, suhu sekitar, pembebanan distribution transformer, loss of life, ambient temperature, loading
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 17 Oct 2025 08:26
Last Modified: 17 Oct 2025 08:26
URI: https://repository.itpln.ac.id/id/eprint/2530

Actions (login required)

View Item
View Item